11B-606.3 Height. Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or...
Search Results "Element"
Commonly Searched Documents
-
11B-606.3 Height
-
11B-607.2 Clearance
11B-607.2 Clearance. Clearance in front of bathtubs shall extend the length of the bathtub and shall be 48 inches (1219 mm) wide minimum for forward approach and 30 inches (762 mm)...
-
11B-213.3.1 Toilet compartments
Where toilet compartments are provided, at least five percent of the toilet compartments, or five percent of the combination of toilet compartments and urinals, but no fewer than one...
-
11B-607.2 Clearance
Clearance in front of bathtubs shall extend the length of the bathtub and shall be 48 inches (1219 mm) wide minimum for forward approach and 30 inches (762 mm) wide minimum for...
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry. Grab bars shall not be provided...
-
11B-608.5.1 Transfer type shower compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches...
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground. ETA Editor's...
-
11B-213.3.1 Toilet compartments
Where toilet compartments are provided, at least five percent of the toilet compartments, or five percent of the combination of toilet compartments and urinals, but no fewer than one...
-
Section 35.151(d) Scope of Coverage (Section-by-Section Analysis)
35.151(d) to clarify that the requirements established by this section, including those contained in the proposed standards, prescribe what is necessary to ensure that fixed or built-in elements...
- Delta Toilet with FlushIQ Technology
-
Section 35.151(d) Scope of coverage (Section-by-Section Analysis)
the requirements established by § 35.151, including those contained in the 2004 ADAAG, prescribe what is necessary to ensure that buildings and facilities, including fixed or built-in elements...
-
1134A.7 Water closets
1134A.7 Water closets. Water closets in bathrooms or powder rooms required to be accessible shall comply with this section.
-
212 and 606 Kitchens, Kitchenettes, Lavatories, and Sinks
212 and 606 Kitchens, Kitchenettes, Lavatories, and Sinks The 1991 Standards, at sections 4.24, and 9.2.2(7), contain technical requirements for sinks and only have specific...
-
Specifications for Alternate Roll-in Shower Controls
Specifications for controls, faucets, and shower spray units for alternate roll-in showers are provided in section 608.5.3. In the final rule, the Board has clarified these...
-
Fixtures
Fixtures TAS 604.3.2 also allows the clear floor space and clearances required at other “fixtures” to overlap the water closet clearance. For purposes of compliance with TAS...
-
G. Women's Spa and Fitness Center Locker Room
G. Women's Spa and Fitness Center Locker Room (1) Defendants will convert the Swiss shower of the current Royal Suite spa massage treatment room to a roll-in shower, pursuant to...
-
§ 36.304(d)
(d) Relationship to alterations requirements of subpart D of this part.
-
Sec.36.304(d)
(d) Relationship to alterations requirements of subpart D of this part.
-
4.21.5 Controls
Faucets and other controls complying with 4.27.4 shall be located as shown in Fig. 37. In shower stalls 36 in by 36 in (915 mm by 915 mm), all controls, faucets, and the shower unit...
-
Side Approach
Side Approach Side reach depth is important to consider in the design and location of sinks. Sinks located in corners may not be fully within reach and the space to the rear of...
-
4.21.5 CONTROLS
Faucets and other controls complying with 4.27.4 shall be located as shown in Fig. 37. In shower stalls 36 in by 36 in (915 mm by 915 mm), all controls, faucets, and the shower unit...
-
4.34.5.1 DOORS
Doors shall not swing into the clear floor space required for any fixture.
-
212 Kitchens, Kitchenettes, and Sinks
1991 Standards for Accessible Design 2010 Standards for Accessible Design What’s New/Different 212.2...
-
4.7.9.3 Height
The counter or rim of the sink shall be no more than 34 inches (865 mm) above the floor or ground. Water spouts must be 28 inches (710 mm) minimum and 36 inches (915 mm) maximum...