Advisory F224.1.2 Guest Room Doors and Doorways....
Search Results "Door Closing Speed"
Commonly Searched Documents
-
F224.1.2 Guest Room Doors and Doorways
-
2.4.4.2. Notice Costs
Movie theaters routinely use “CC” and “AD” or “DV” to indicate the availability of closed movie captioning and audio description in their communications, and the Department’s research indicates...
-
404.2.2 Double-Leaf Doors and Gates
At least one of the active leaves of doorways with two leaves shall comply with 404.2.3 and 404.2.4.
-
404.2.2 Double-Leaf Doors and Gates
At least one of the active leaves of doorways with two leaves shall comply with 404.2.3 and 404.2.4.
-
Height: ADA Standard Section 407.3.3.1
Section 407.3.3.1 covers the current ADA Standards for the height requirements of an elevators reopening device.
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
Vertical Clearance: ADA Standard Section 307.4
Section 307.4 covers the current ADA Standards for vertical clearance.
-
11B-307.4 Vertical clearance
Exception: Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground. ...
-
1132A.3 Width and height of interior doors and secondary exterior doors
Doors shall comply with the following:...
-
Opening Force [§404.2.9]
hinged doors (no maximum specified) latch bolts and other devices that keep doors or gates closed The 5 lbf maximum applies to the continuous application of force necessary...
-
11B-404.2.4.3 Recessed doors and gates
, measured perpendicular to the face of the door or gate...
-
Maneuvering Clearances at Doors [4.13.6]
Maneuvering Clearances at Doors [4.13.6] Pull-side clearance beyond the door swing provides space for a forward reach to door hardware....
-
11B-404.2.4.3 Recessed doors and gates
, measured perpendicular to the face of the door or gate...
-
11B-404.2.4.3 Recessed doors and gates
, measured perpendicular to the face of the door or gate...
-
7.5. Reporting, Recordkeeping, and Other Compliance Requirements
Movie theaters routinely use “CC” and “AD” or “DV” to indicate the availability of closed movie captioning and audio description in their communications, and the Department’s research indicates...
-
404.2 Manual Doors, Doorways, and Manual Gates
Manual doors and doorways and manual gates intended for user passage shall comply with 404.2....
-
404.2 Manual Doors, Doorways, and Manual Gates
Manual doors and doorways and manual gates intended for user passage shall comply with 404.2....
-
Courtesy Phones
Comment. Section 217.1 lists various types of public telephones covered by this section. Commenters requested that courtesy phones be addressed along with other types of public...
-
3. Bank of House Phones
3. If one house phone or one bank of house phones is provided on a given floor, does at least one house phone have the following features: [ADA Stds. 4.1.3(17)]
-
R218 Doors, Doorways, and Gates (Section-by-Section Analysis)
R218 Doors, Doorways, and Gates (Section-by-Section Analysis) Doors, doorways, and gates to pedestrian facilities such as transit shelters must comply with applicable technical requirements...
-
4.13.12* Automatic Doors and Power-Assisted Doors
If an automatic door is used, then it shall comply with ANSI/BHMA A156.10‒1985. Slowly opening, low-powered, automatic doors shall comply with ANSI A156.19‒1984....
-
11B-411.3.4 Door delay
Door delay shall comply with Section 11B-407.3.5....
-
11B-411.3.4 Door delay
Door delay shall comply with Section 11B-407.3.5....
-
11B-411.3.4 Door delay
Door delay shall comply with Section 11B-407.3.5....