Users may slide off the seat and fall onto the floor of the shower while reaching for the shower controls and hand-held showerhead. Requirement: 4.21.2 Size and Clearances....
Search Results "Lavatory Clear Floor Space"
Commonly Searched Documents
-
Error/Omission: When a transfer shower is used, it is often larger than the required 36" x 36" size.
-
Basic Features
Careful planning and design will incorporate elements such as a wider entrance door, adequate clear floor space, appropriate placement and models of fixtures and furniture, and grab bars...
-
Utility Sinks
Ensure that the height of the counter or rim surrounding the utility sink is not more than 34 inches (865 millimeters) above the ground or floor space and that the bottom of the bowl is...
-
Building Requirement: ADA Standard Section 217.4.3
Section 217.4.3 covers scoping requirements in the current ADA Standards for TTYs on the floor of public and private buildings.
-
POWDER ROOM
[DSA-AC] A room containing a water closet (toilet) and a lavatory, and which is not defined as a bathroom....
-
Diagonal Curb Ramps: ADA Standard Section 406.6
Section 406.6 covers the current ADA Standards for diagonal curb ramps.
-
H. Door Maneuvering Clearance
.: entry door, connecting room door, bathroom doors and other passage doors) in every accessible guestroom/suite, are there at least 18" of clear floor space on the latch side for persons...
-
4.13.6 Maneuvering Clearances at Doors
The floor or ground area within the required clearances shall be level and clear....
-
Are closet doors and pantry doors required to comply?
pantries, cabinets and other storage elements not providing user passage do not have to comply with provisions for doors, but must meet requirements for storage (§811), including those for clear...
-
4.26.2* SIZE AND SPACING OF GRAB BARS AND HANDRAILS
If handrails or grab bars are mounted adjacent to a wall, the space between the wall and the grab bar shall be 1-1/2 in (38 mm) (see Fig. 39(a), (b), and (c))....
-
Telescopes and Periscopes
Provide a clear floor or ground space that is adjacent to (and may overlap) an outdoor recreation access route at all accessible telescopes and periscopes so that someone using a wheelchair...
-
11B-404.2.9 Door and gate opening force
is 35 inches (889 mm) minimum above the floor or ground surface....
-
11B-809.7 Accessible routes
The accessible route shall adjoin or overlap clear floor spaces and connect all exterior doors....
-
Toilet Buildings and Pit Toilets
Portions of the turning space may overlap the toilet clear floor space (figure 112)....
- Figure 705.1 Size and Spacing of Truncated Domes – Drawing from the U.S. Access Board
-
11B-220.1.2 Two automatic teller machines or fare machines
machines or fare machines are provided at a location, one shall comply with Sections 11B-707.2 through 11B-707.8 and one shall comply with Sections 11B-309 _|Operable Parts|_, 11B-707.2 _|Clear...
-
11B-809.9.7 Exposed pipes and surfaces
Exposed water supply and drain pipes under sinks and lavatories shall comply with Section 11B-606.5....
- Inpro Corporation ENDURANT® Floor-to-Ceiling Mounted Partitions
- Takeform Fusion Signage Floor Directional Type B.2
-
§100.205(c)
(c) All covered multifamily dwellings for first occupancy after March 13, 1991 with a building entrance on an accessible route shall be designed and constructed in such a manner that—
-
Circulation Paths
Objects that overhang circulation paths do not provide clear headroom....
-
Features of Accessible Exam Tables
Removable/adjustable support rails with continuous gripping surfaces 2. 30” X 48” minimum clear floor space adjacent to exam table and adjoining accessible route 3....