A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or forward approach shall be provided at the kitchen sink and all other fixtures or appliances...
Search Results "Clear Ground Space"
-
1133A.2, Item 2
-
2.9.1 Natural Elements
However, safety regulations or Forest Service construction and maintenance standards may define clear space and limit the allowable extension of natural protruding objects over the ORAR...
-
1133A.2, Item 2
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or forward approach shall be provided at the kitchen sink and all other fixtures or appliances...
-
1130A.1 General
An accessible route shall be provided through all rooms and spaces of the dwelling unit....
-
Kitchens, Kitchenettes, or Wet Bars [9.2.2(7)]
Kitchens, Kitchenettes, or Wet Bars [9.2.2(7)] Clear floor space for either a forward or a side approach is permitted for cabinets, counters, sinks, and appliances....
-
309 Operable Parts
Specifications for operable parts address clear floor space, height, and operating characteristics. Operable parts are required to be located with the reach ranges specified in 308....
-
Question 10
Is the accessible entrance into the building free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the latch side of the door...
-
H6
If the entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the door swing?...
-
1133A.2.1, Item 2
U-shaped kitchens, designed with a cooktop or sink located at the base of the U, which provides a knee and toe space in accordance with Section 1133A.7 to allow for a forward approach, shall...
-
Lavatories and Mirrors [4.19]
In those few toilet or bathrooms permitted to be adaptable, base cabinetry is allowed as long as required clear floor space and knee and toe clearances are available when the cabinet is...
-
6.11.1 Natural Elements
However, safety regulations or Forest Service construction and maintenance standards may define clear space and limit the allowable extension of natural protruding objects over the beach...
-
1133A.2.1, Item 2
U-shaped kitchens, designed with a cooktop or sink located at the base of the U, which provides a knee and toe space in accordance with Section 1133A.7 to allow for a forward approach, shall...
-
1134A.5 Bathtubs
Floor space....
- Doug Mockett & Company SDH1 Sliding Door Hardware
-
11B-405.9.2 Curb or barrier
A curb or barrier shall be provided that prevents the passage of a 4-inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor or ground...
-
11B-405.9.2 Curb or barrier
A curb or barrier shall be provided that prevents the passage of a 4-inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor or ground...
-
Performance and the Surface Deficiency Score
A digital level and tape measure were used to identify instances along the accessible routes and at clear floor spaces where the surface running slope exceeded 1:16 (6.25%); the cross slope...
-
Question 19
Are the entrances to accessible public restrooms and fitting rooms free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the...
-
D6
If an entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the swing of a hinged door?...
-
Forward Approach
Clear floor space must be provided to the face of the unit since the seated forward reach does not extend much beyond the toes....
-
Side Reach [§308.3]
The maximum reach depth for this range is 10” measured from the available clear floor space....
- AJW Architectural Products U716 Series 16"W x 20"H Channel Frame Mirror w/ Mounted Shelf - Plate Glass Surface
