A minimum 18 inch vertical clearance (specified for recessed handrails) may place elements above maximum reach heights....
Search Results "Door Height"
Commonly Searched Documents
-
Size and Spacing of Grab Bars and Handrails [4.26.2]
-
Elevated Dune Crossings
Locate handrails continuously along both sides of the dune crossing at a height of 34 inches (865 millimeters) to 38 inches (965 millimeters) above the walking surface....
-
iii. Radiological Diagnostic equipment
Positron Emission Tomography (PET), and X-rays, including Computerized Axial Tomography (CAT) scans and mammography, are difficult to access for individuals with disabilities because of the height...
-
211 Drinking Fountains
(This can be accommodated by the use of a "hi-lo" fountain; by providing one fountain accessible to those who use wheelchairs and one fountain at a standard height convenient for those who...
-
Location
Van-accessible parking spaces located in parking garages may be clustered on one floor (to accommodate the 98-inch minimum vertical height requirement)....
-
III-2.1000 General
Likewise, being only five feet in height may prove to be an insurmountable barrier to an individual whose ambition is to play professional basketball....
-
E. Restaurants and Concessions:
to all dining counters so that at least five (5) percent of the seating and standing spaces at the counter provide a clear floor space positioned for a forward approach at an accessible height...
-
Location
Van-accessible parking spaces located in parking garages may be clustered on one floor (to accommodate the 98-inch minimum vertical height requirement)....
-
11B-604.8.1.5 Grab bars
Where separate grab bars are required on adjacent walls at a common mounting height, an L-shaped grab bar meeting the dimensional requirements of Sections 11B-604.5.1 and 11B-604.5.2 shall...
-
11B-705.1.1.2 Dome spacing
ETA Editor's Note This Figure has not been updated to reflect the text at 11B-705.1.1.1 regarding dome height. DSA-AC's Advisory Manual still has this same Figure....
-
11B-809.10.5.2 Reinforcement for grab bars
The grab bar reinforcement shall be 8 inches (203 mm) minimum in height. b....
- Hadrian Inc. Specialty Lockers
-
Raised Letter Braille requirement - Exterior
The Fire Department is requiring the developer to provide the suite number above the entrance door to each suite, 8’ AFG Is the suite number considered part of the address, and therefore...
-
John Brabyn, Ph.D., Director of Rehabilitation Engineering Research, Center on Low Vision and Blindness (NIDRR), Smith-Kettlewell Eye Research Institute
Distinguish doors and doorways with visual contrast. Highlight glazed doors and side panels with prominent signs, logos or decorative features at eye level....
- Activar JL Industries ORBIT SERIES - LOW PROFILE CABINET
- GE Profile™ Series 30" Slide-In Double Oven Electric Convection Range PS950EFES
- Caroma® USA Caravelle Smart 270 One Piece Toilet
- ViewPlus Technologies VP Cub Braille Printer
-
A4.22.3 Clear Floor Space
A turning circle or T-turn, the clear floor space at the lavatory, and maneuvering space at the door must be considered when determining the possible wall locations....
-
Best Practice Recommendations for Layout Planning
Doors should be propped open at the start and end of each session, and event staff should be on hand to open doors during sessions if needed....
-
Section 37.129 Types of Service
The local planning process should decide whether, or in what circumstances, this service is to be provided as door-to-door or curb-to-curb service....
-
Section G: Ramps
(§405.3) G3 Is the rise (height) for any ramp run 30" or less?...
-
11B-308.3.2 Obstructed high reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...