4.1.2(5)(b)
(b) One in every eight accessible spaces, but not less than one, shall be served by an access aisle 96 in (2440 mm) wide minimum and shall be designated “van accessible” as required by 4.6.4...
-
213.3.1 Toilet Compartments
closets totals six or more fixtures....
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1....
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1....
-
Section B: Passenger Drop-Off Area
Yes No N/A Comments/Remedies B1 Is the vehicle pull-up space on a level surface, with slopes not exceeding 1:48 in all directions?...
-
§ 382.21 Aircraft accessibility
(2) Aircraft with 100 or more passenger seats shall have a priority space in the cabin designated for stowage of at least one folding wheelchair; (3) Aircraft with more than one aisle...
- Methods for Placing a Slope Tool on the Surface
-
Minimum Clear Corridor Width
A few commenters from the disability community advocated a minimum clear corridor width of 48 inches....
- Kompan, Inc. M175 - Water Lilies Spring Rider
-
This is a great unit but it's not "recessed", it's semi-recessed.
If you place this unit next to the accessible lavatory or other required clear space and don't allow room for the projection, it may interfere with the minimum required clear floor space...
-
407.4.8.1.3 Floor Arrival
407.4.8.1.3 Floor Arrival. As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate....
-
Clear Width [4.8.3]
A maximum clear width is not specified....
-
M102.1 Defined Terms (Section-by-Section Analysis)
decided to add six additional terms to this section; end transfer surface, examination chair, imagining [sic] equipment with bores, imagining [sic] bed, side transfer surface, and wheelchair space...
-
609 Grab Bars
Section 609 covers grab bars at water closets, bathtubs, and showers. Specifications address size, spacing, position, surfaces, fittings, and structural strength....
-
11.1 Q. Under the individual building test, how is the second step of the test performed, which involves measuring the slope of the finished grade between the entrance and applicable arrival points?
A. The slope is measured at ground level from the entrance to the top of the pavement of all vehicular and pedestrian arrival points within 50 feet of the planned entrance, or, if...
-
M305.3.1 Length (Section-by-Section Analysis)
The MDE Advisory Committee supported the proposed technical provisions, but recommended adding additional criteria for standing supports on raised platforms with wheelchair spaces....
-
F217.4.2 Floor Requirement
Where at least one public pay telephone is provided on a floor of a building, at least one public TTY shall be provided on that floor....
-
Maps/floor plans
Maps/floor plans: b. Provide at the front desk tactile maps of the Museum and floor plan that visitors can borrow. See 28 C.F.R. § 36.303....
-
How Broken Overhead Channels Guarantee Subterranean Flooding
When property owners discover an expanding, highly destructive puddle of water spreading across their finished basement floor, their immediate, frantic reaction is to blame the underground...
-
11B-707.7.1 Visibility
The display screen shall be visible from a point located 40 inches (1016 mm) above the center of the clear floor space in front of the machine....
-
11B-707.7.1 Visibility
The display screen shall be visible from a point located 40 inches (1016 mm) above the center of the clear floor space in front of the machine....
-
Visibility: ADA Standard Section 707.7.1
The display screen shall be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the machine....
-
11B-411.4.7.4 Button spacing