Is there clear maneuvering floor space in front of each accessible door (see Figure 25 in the appendix for measurements) and on the pull side, is there at least 18 inches clear floor space...
Search Results "Floor Surface"
-
7c.
-
¾ Inch Minus Limestone
After the same two days of uncharacteristically heavy rainfall (as noted in the ¼ inch minus segment), the surface had evidence of water pooling on the surface, as there were lines of pine...
-
2. Typical Issues for People Who are Blind or Have Low Vision
is more than 27 inches above the floor....
-
Part 2. Typical Issues for Voters Who are Blind or Who Have Low Vision
is more than 27 inches above the floor....
-
Scoping [4.1.3(5)]
Under ADAAG, a floor must contain occupiable space in order to be considered a "story."...
-
Elevator Exemption (Preamble, Section-by-Section Analysis)
ground floor. 4....
-
Elevator Exemption (Section-By-Section Analysis and Response to Comments)
ground floor. 4....
-
11B-903.4 Back support
Back support shall be 48 inches (1219 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (457 mm) minimum above the seat...
-
Running Slope of Ramps Deployed to Roadways or Curb-Height Bus Stops
Low floor buses have a lower vehicle floor (typically 15 inches or less above the roadway) that permits a flat – rather than stepped – area at doorways....
-
11B-403.5.1 Clear width
Except as provided in Sections 11B-403.5.2 and 11B-403.5.3, the clear width of walking surfaces shall be 36 inches (914 mm) minimum....
-
11B-403.5.1 Clear width
Except as provided in Sections 11B-403.5.2 and 11B-403.5.3, the clear width of walking surfaces shall be 36 inches (914 mm) minimum....
-
5.8.2.7 Base Support Allowance Recommendation
of 4 inches above the floor at a depth of 28 inches from the front edge of the breast platform....
-
Problem Two (Protruding Objects)
Problem Two: A wall-mounted display case protrudes seven inches from the wall and the bottom of the case is 40 inches above the floor....
-
M. Reach Range
Are the rod and shelf in the clothes closet or wall mounted unit within 54" of the floor for side approach or 48" of the floor for forward approach so persons who use wheelchairs can approach...
-
Size: ADA Standard Section 604.8.1.1
Section 604.8.1.1 covers the current ADA Standards for the size of wheelchair accessible compartments.
-
Door and Gate Hardware: ADA Standard Section 404.2.7
Section 404.2.7 covers the current ADA Standards for door and gate hardware.
-
1007.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
Elevator Operable Parts
The proposed rule specified that call buttons be located 35 to 48 inches above the floor (407.2.2)....
-
A4.1.3(10)
A4.1.3(10) If an odd number of drinking fountains is provided on a floor, the requirement in 4.1.3(10)(b) may be met by rounding down the odd number to an even number and calculating 50%...
-
801.1 Scope
For example, 806 addresses guest rooms in transient lodging facilities while 902 contains the technical specifications for dining surfaces....
-
903.4 Back Support
Back support shall be 42 inches (1065 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (455 mm) minimum above the seat...
-
801.1 Scope
For example, 806 addresses guest rooms in transient lodging facilities while 902 contains the technical specifications for dining surfaces....
-
711.4.1 Through penetrations
Exceptions: Penetrations by steel, ferrous or copper conduits, pipes, tubes, vents, concrete, or masonry through a single fire-resistance-rated floor assembly where the annular...
-
Transition Plate