The element-by-element safe harbor referenced in Sec. 36.304(d)(2) has no effect on new or altered elements in existing facilities that were subject to the 1991 Standards on the date that...
Search Results "Postal Facility"
Commonly Searched Documents
-
Noncomplying new construction and alterations
-
Noncomplying new construction and alterations
The element-by-element safe harbor referenced in Sec. 35.150(b)(2) has no effect on new or altered elements in existing facilities that were subject to the 1991 Standards or UFAS on the...
-
Scoping Requirement for Alarms
The Board proposed covering facility alarm systems (other than fire alarm systems) that do not instruct occupants to evacuate the facility but provide other warning information, such as...
-
405.2 Slope
EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due...
-
Technical Memorandum TM 2012-03 Shopping Centers or Shopping Malls
TM 2012-03 Shopping Centers or Shopping Malls Effective Date: November 15, 2012 2012 TAS Reference: 206.2.3, Exception 1; 206.2.4, Exception 3 If a private building or facility...
-
Accessible Golf Courses
Bush, New Freedom Initiative, February 1, 2001 The recreation facility guidelines described in this guide focus on newly designed or newly constructed and altered golf courses and...
-
405.2 Slope
EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due...
-
Areas of sport activity. (Section-by-Section Analysis)
The Department is considering limiting the application of this requirement in existing facilities that have multiple areas of sport activity that serve the same purpose. ...
-
405.2 Slope
EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due...
-
Section 35.151 New Construction and Alterations (Section-by-Section Analysis)
This exception is now contained in the title III regulation and in the 1991 Standards (applicable to both public accommodations and facilities used by public entities), so it has applied...
-
New Construction
New buildings and facilities must comply with the new construction provisions of the ADA Standards for Accessible Design (without the elevator exemption) or the Uniform Federal Accessibility...
-
F. Taking Photographs
It is likely that many other people in your decision-making process will need to review information about the facility you are surveying, so try to record each element that you survey with...
-
Step One: Accessible Shelter Quick-Check Survey
on hilly sites and those that have not been renovated, remodeled, or altered since 1992, before completing the detailed checklist, it may be better to do a pre-test that can rule out a facility...
-
Scoping and technical requirements applicable to "places of lodging." (Section-by-Section Analysis)
Some commenters agreed with the application of transient lodging standards to places of lodging in general, but disagreed about the characterization of certain types of facilities as covered...
-
Noncomplying new construction and alterations. (Section-by-Section Analysis)
The element-by-element safe harbor referenced in Sec. 36.304(d)(2) has no effect on new or altered elements in existing facilities that were subject to the 1991 Standards on the date that...
-
STEP 1: OBTAIN COPIES OF THE ADA REQUIREMENTS AND GIVE THEM TO YOUR ARCHITECT AND BUILDING CONTRACTOR.
To ensure that persons with disabilities can use lodging facilities like everyone else, all newly constructed lodging facilities must comply with building requirements called the ADA Standards...
-
TTY Scoping [4.1.3(17)(c)]
Recommendations: From a practical standpoint, it would be considered good design to place additional units at some multi-facility sites or large buildings....
-
227 Sales and Service
Accessible Design What’s New/Different 7.3 Check-out Aisles Exception: In alterations, at least one check-out aisle shall be accessible in facilities...
-
ACTIONS TAKEN BY CITY OF WAUKEGAN
In 1993, the City of Waukegan conducted a self-evaluation of its programs and facilities. ...
-
1009.8 Two-way communication
are not required at the landings serving only service elevators that are not designated as part of the accessible means of egress or serve as part of the required accessible route into a facility...
- USDA Forest Service Built Environment Image Guide (BEIG)
-
806 Transient Lodging Guest Rooms
In multi-story facilities, relocating or re-routing these elements may not be possible, limiting options for providing access....
-
202.4 Alterations Affecting Primary Function Areas
If elements of a path of travel at a subject building or facility that have been previously constructed or altered in accordance with the April 1, 1994 Texas Accessibility Standards (TAS...
-
Issue 15: How can the potential conflict between the goals of zero net energy and accessibility for low vision persons be resolved?
And Kurt, you talked about the demands on hospitals and health care facilities....