The number of persons for which the means of egress of a building or portion of a building is designed....
Search Results "Floor Designation"
-
Occupant Load
-
Site
A parcel of land bounded by a property line or a designated portion of a public right-of-way....
-
Catch Pool
A pool or designated section of a pool used as a terminus for water slide flumes....
-
11B-707.7.1.1 Vertically mounted display screen
mounted vertically or no more than 30 degrees tipped away from the viewer, the center line of the display screen and other display devices shall be no more than 52 inches (1321 mm) above the floor...
-
6.5
6.5 Each wheelchair space shall comply with the size requirements set forth in § 4.33.2 of the Standards, be level and satisfy the floor surface requirements as set forth in § 4.33.4...
-
603.4 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor. [ECTCR UFAS 4.25.3, Fig. 38]...
-
11B.707.7.1.2 Angle-mounted display screen
mounted between 30 degrees and 60 degrees tipped away from the viewer, the center line of the display screen and other display devices shall be no more than 44 inches (1118 mm) above the floor...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
407.8.3.1 Unobstructed Forward Reach
maximum protrusion within the length of the vertical reference plane of the ICT, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm) high minimum above the floor...
-
§ 35.151(b)(4)(ii)(A)
(A) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms, and...
-
M20
Is there a horizontal grab bar at least 36 inches long securely mounted behind the toilet 33 to 36 inches above the floor with one end no more than 6 inches from the side wall?...
-
Free-standing and Post-mounted Objects
Where objects are mounted above 27 inches from the ground or floor, overhangs are limited to 12 inches. This is based on standard measures for cane sweep....
-
§ 35.151(b)(4)(ii)(A)
(A) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms, and...
-
§ 38.113(d)(4) Exception
Retrofitted vehicles shall be coordinated with the platform in existing stations such that the horizontal gap shall be no greater than 4 inches and the height of the vehicle floor, under...
-
11B.707.7.1.1 Vertically mounted display screen
mounted vertically or tipped away from the viewer less than 30 degrees, the center line of the display screen and other display devices shall be no more than 52 inches (1321 mm) above the floor...
-
Location
Location of Swing Away Grab Bars (Linido grab bars pictured here) Rear-mounted (either floor or wall), swing away (or fold up) grab bars (e.g., Linido or Bobrick) on both sides of...
-
233.1 General
In sleeping rooms with more than 25 beds covered by this part, a minimum of 5% of the beds shall have clear floor space complying with section 806.2.3. 2....
-
1118B.3
SECTION 1124B - GROUND AND FLOOR SURFACES 1124B.1 General. ...
- Willoughby Industries WAW-2333-DMF AquaWave® Three Station Solid Surface Lavatory System for Deck Mounted Faucets
- Willoughby Industries WAF-440 AquaFount® Four Station Solid Surface Washfountain
- Willoughby Industries WAW-2311-DMF AquaWave® Single Station Solid Surface Lavatory System Deck Mounted Faucet
- Willoughby Industries WAW-2322-DMF AquaWave® Two Station Solid Surface Lavatory System for Deck Mounted Faucets
-
Section 35.151 New Construction and Alterations (Section-by-Section Analysis)
Section 35.151, which provides that those buildings that are constructed or altered by, on behalf of, or for the use of a public entity shall be designed, constructed, or altered to be readily...
-
STEP 1: OBTAIN COPIES OF THE ADA REQUIREMENTS AND GIVE THEM TO YOUR ARCHITECT AND BUILDING CONTRACTOR.
with disabilities can use lodging facilities like everyone else, all newly constructed lodging facilities must comply with building requirements called the ADA Standards for Accessible Design...