5.4.3 Transfer Support Height for M301 and M302 Description: Transfer support height applies to the vertical distance that the gripping area of the support is above the transfer...
Search Results "Medical Exam"
Commonly Searched Documents
-
5.4.3 Transfer Support Height for M301 and M302
-
M305.4 Leg Supports (Section-by-Section Analysis)
Four commenters (medical association, accessibility consultant, disability rights organization, and a state agency) agreed with requiring leg supports when stirrups are provided....
-
Entry Doors
Entry Doors Under the ADA Standards for Accessible Design, an accessible doorway must have a minimum clear opening width of 32 inches when the door is opened to 90...
-
a. Transfer Surface Adjustability
The MDE NPRM proposed that the same transfer surface height range of 17 inches minimum to 19 inches maximum be applied to both diagnostic equipment used in the supine, prone, or...
-
M302.3.2 Leg Supports (Section-by-Section Analysis)
The MDE NPRM did not propose to require stirrups to provide a method of supporting, positioning, and securing the patient’s legs for diagnostic equipment used by patients in the...
-
Healthcare Stories - Mary Smith
Requires the Registered User plan or above. Login!
-
M301.4.2 Clearance Around Base
The base of diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the...
-
M301.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the...
-
M301.4.2 Clearance Around Base
[See subsections ...]
-
M201.1 Application by Enforcing Authority
The enforcing authority shall specify the number and type of diagnostic equipment that are required to comply with the MDE Standards.
-
F223.2.1 Facilities Not Specializing in Treating Conditions That Affect Mobility
In facilities not specializing in treating conditions that affect mobility, at least 10 percent, but no fewer than one, of the patient sleeping rooms shall provide mobility features...
-
M101.2 Application
Sections M301 through M304 shall be applied to diagnostic equipment, based on the patient positions that the equipment supports, during patient transfer and diagnostic use. Sections...
-
M306.1 General
Where instructions or other information necessary for performance of the diagnostic procedure is communicated to the patient through the diagnostic equipment, the instructions and...
-
M101.3 Existing Diagnostic Equipment
The MDE Standards do not address the applicability of scoping or technical requirements to existing diagnostic equipment. Enforcing authorities, such as the Department of Justice or...
-
M306 Communication
[See subsections ...]
-
A. Chapter 2: M201 Scoping
In the final rule, Chapter 2 establishes that the enforcing authority will determine the number and types of diagnostic equipment to which the MDE Standards will apply. There was...
-
B. Regulatory Flexibility Act
The Regulatory Flexibility Act (RFA) requires federal agencies to analyze the impact of regulatory actions on small entities, unless an agency certifies that the rule will not have a...
-
M201.1 Enforcing Authority (Section-by-Section Analysis)
The MDE NPRM proposed to explain that the enforcing authority would specify the minimum number of types of accessible diagnostic equipment that would be required to comply with the...
-
M306 Communication (Section-by-Section Analysis)
M306 in the final rule provides the technical criteria for communication from the diagnostic equipment to the patient.
-
12112(d)(2)(B) Acceptable inquiry
(B) Acceptable inquiry A covered entity may make preemployment inquiries into the ability of an applicant to perform job-related functions.
-
Users and Needs
Users and Needs Facility Types and User Profiles. Many of the facilities reviewed were healthcare and residential facilities specifically designed for older adults. This...
-
M101.2 Application
The standards shall be applied to diagnostic equipment based on the patient positions that the equipment is designed to support. Where diagnostic equipment is designed to support...
-
M201.1 Enforcing Authority
The enforcing authority specifies the minimum number of types of accessible diagnostic equipment that are required to comply with the standards in different types of health care...
-
M306 Communication
[See subsections ...]