5.4.2 Transfer Support Length for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The transfer support should be a minimum length of 15 inches positioned so that...
Search Results "Medical Exam"
Commonly Searched Documents
-
5.4.2 Transfer Support Length for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
-
5.3 Transfer Sides Recommendations
5.3 Transfer Sides Recommendations
-
5.4.5 Transfer Support Position for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.5 Transfer Support Position for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The transfer gripping surface should be located within the minimum and maximum...
-
5.4.9 Interruptions Along Transfer Support Gripping for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.9 Interruptions Along Transfer Support Gripping for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The bottom of the transfer support shall have no...
-
M305.2.1 Location
Transfer supports shall be located within reach of the transfer surface and shall not obstruct transfer onto or off of the surface when in position.
-
DREDF: Part 1 Barriers to Healthcare-Tables and Scales
Requires the Registered User plan or above. Login!
- Welch Allyn Scale-Tronix® Integrated Scales
- Bobrick Charting Station/Shelf B-7816
-
9.5 Do the ADA's Pre-Employment Inquiry and Confidentiality Restrictions Prevent an Employer from Filing Second Injury Fund Claims?
., an employer may make such medical inquiries and require a medical examination after a conditional offer of employment, and before a person starts work, so long as the examination or inquiry...
-
Chapter 3: Technical Requirements
[See subsections ...]
-
Chapter 1: Application and Administration
[See subsections ...]
-
Wheelchair Space
Space for a single wheelchair and its occupant.
-
M101.4 Equivalent Facilitation
The use of alternative designs or technologies that result in substantially equivalent or greater accessibility and usability than specified in the MDE Standards is permitted.
-
I. Executive Summary
[See subsections ...]
-
M102.2 Undefined Terms (Section-by-Section Analysis)
The MDE NPRM proposed that the meaning of terms not defined in proposed M102.1 or in regulations or policies issued by an enforcing authority, be defined by collegiate dictionaries...
-
A. Chapter 1: Application and Administration (Section-by-Section Analysis)
In the final rule Chapter 1 establishes the purpose and the general requirements for the application of the MDE Standards. This chapter received 21 comments and no recommendations...
-
Chapter M3: Technical Criteria
[See subsections ...]
-
M101.3 Equivalent Facilitation
The use of alternative designs or technologies that result in substantially equivalent or greater accessibility and usability than specified in the standards is permitted.
-
Chapter M1: Application and Administration
[See subsections ...]
-
6. Regulatory Analyses
[See subsections ...]
-
M101.3 Equivalent Facilitation
The use of alternative designs and technologies that result in substantially equivalent or greater accessibility than specified in the proposed standards is permitted. Generally,...
-
Sec.36.102(a)(3)
(3) Private entity that offers examinations or courses related to applications, licensing, certification, or credentialing for secondary or postsecondary education, professional, or...
-
M302.2.3 Size
Transfer surfaces shall be 21 inches (610 mm) wide minimum and 17 inches (430 mm) deep minimum. The size of transfer surfaces shall be measured from center points of their opposing...
-
M302.3.2 Leg Supports
Where stirrups are provided, leg supports shall also be provided and comply with M305.4.