Doors and Gates in Series [§404.2.6] At hinged or pivoted doors or gates in series, a separation is required that is at least 48” plus the width of doors or gates swinging into the space...
Search Results "Urinal Clear Floor Space"
Commonly Searched Documents
-
Doors and Gates in Series [§404.2.6]
-
4.9.4 HANDRAILS
At the top, the extension shall be parallel with the floor or ground surface....
-
RECOMMENDATIONS
The latter includes studies to determine optimum design specifications, such as: toilet height and location, grab bar height, positioning, and location; clear floor space; and size of fixtures...
-
Re: Section 307 Protruding Objects
The more blatant inconsistency is the lavatory, which is required to be 17" deep minimum due to the required forward approach clear floor/knee and toe space, and must provide knee clearance...
-
4.9.4(3)
(3) The clear space between handrails and wall shall be 1‒1/2 in (38 mm)....
-
4.8.5(3)
(3) The clear space between the handrail and the wall shall be 1 - 1/2 in (38 mm)....
-
11B-812.8.7 Location
Signs shall be permanently posted either immediately adjacent to the vehicle space or within the projected vehicle space width at the head end of the vehicle space....
-
11B-812.8.7 Location
Signs shall be permanently posted either immediately adjacent to the vehicle space or within the projected vehicle space width at the head end of the vehicle space....
-
§ 36.403(e)(2)
(2) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms, and...
-
Sec.36.403(e)(2)
(2) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms, and...
-
14.2 Q. If both open and covered parking spaces are provided, how many of each type must be accessible?
Thus, if a project provides different types of parking such as surface parking, garage, or covered spaces, some of each must be made accessible....
-
11B-604.5.2 Rear wall
Exceptions: The rear grab bar shall be permitted to be 24 inches (610 mm) long minimum, centered on the water closet, where wall space does not permit a length of 36 inches (914 mm...
- SmartCells Flooring: SmartCells Responsiveness
-
Can accessible spaces required for one parking facility be located in another one instead?
Accessible spaces required for one parking facility can be located in a different parking facility on the site if it results in substantially equal or greater access and convenience for...
-
B4
For van-accessible spaces (particularly in a garage or parking structure), is there vertical clearance of at least 98 inches (8 feet - 2 inches) for the vehicle route to the parking space...
-
9.4 POST OFFICE BOXES
Accessible post office boxes shall be located in the second or third set of modules from the floor, approximately 12 in to 36 in (305 mm to 915 mm) above the finished floor....
-
Boundaries of Angled Parking Spaces
An architect asked me about allowable slopes in angled parking stalls and whether the "triangular sections" at the head of the stall and the foot of the stall could have slopes >...
-
11B-216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5....
-
Orientation (slide 12)
Floor-plan organization, if it’s consistent from floor to floor, it’s much easier for people to navigate....
-
Story
That portion of a building included between the upper surface of a floor and upper surface of the floor or roof next above....
-
306.2.1 General
Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2....
-
306.2.1 General
Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2....
-
306.2.1 General
Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2....
-
306.2.1 General
Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2....