If alterations of single elements, when considered together, amount to an alteration of a room or space in a building or facility, the entire room or space shall be made accessible....
Search Results "Clear Deck Space"
-
11B-202.3.3 Alteration of single elements
-
Kitchens and Kitchenettes
Section 4.34.2 of the UFAS requires a clear turning space at least 60 inches in diameter or an equivalent T-shaped turning space in kitchens....
-
Accessible Fishing Piers and Platforms
If railings, guards, or handrails are provided, accessible edge protection and clear floor or ground space at accessible railings are required....
-
Mounting Height and Location
Tactile signs are required to be located alongside the latch side of doors so that clear floor space at least 18 by 18 inches, centered on the tactile characters, is provided outside the...
-
Alterations
The seat of at least one spring rocker is between 11 inches (280 mm) and 24 inches (610 mm) maximum, and clear floor or ground space and maneuvering space is provided. ...
-
New Construction
Designers should use the Chapter 3 building blocks that address reach ranges, knee and toe clearance, clear floor space, protruding objects and operable parts when designing the space....
-
Check-Out Aisles [7.3]
For facilities with less than 5,000 square feet of selling space, at least one check-out aisle must be accessible....
-
Transfer Type Shower Compartments: ADA Standard Section 608.2.1
Section 608.2.1 covers the current ADA Standards for the size and clearances of transfer type shower compartments.
-
REPAIR
The definition is clear that repair is limited to work on an item or part and does not apply to a renovation, rehabilitation or renovation to an existing building in the event of fire or...
-
Handrails: ADA Standard Section 405.8
Section 405.8 covers the current ADA Standards for ramp handrails.
-
REPAIR
The definition is clear that repair is limited to work on an item or part and does not apply to a renovation, rehabilitation or renovation to an existing building in the event of fire or...
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
1009.5.1 Transfer Platform
Transfer platforms shall provide 19 inches (485 mm) minimum clear depth and 24 inches (610 mm) minimum clear width. Figure 1009.5.1 Size of Transfer Platform...
- PlayLSI Tree Stump Transfer Module
- S.R. Smith PAL2 202-0000 Pool Lift
- Mockett SDH1-SSS Sliding Door Hardware Set
-
4. Organization of Technical Criteria
space, and height of the breast platform....
-
1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
1010.1.7 Door arrangement
Space between two doors in a series shall be 48 inches (1219 mm) minimum plus the width of a door swinging into the space....
-
1010.1.7 Door arrangement
Space between two doors in a series shall be 48 inches (1219 mm) minimum plus the width of a door swinging into the space....
-
5. Discussion of Proposed Standards
The Access Board is committed to writing standards that are clear, concise, and easy to understand so that persons who use the standards know what is required. Question 4....
-
810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
Covered Multifamily Dwellings
The Department believes that this definition is sufficiently clear to identify ground floor units, and that therefore a separate definition for "ground floor unit" is unnecessary....