If more than 25 parking spaces are provided to voters, see the 2010 Standards for the number of accessible parking spaces required. (§208.2) Yes No N/A Comments/Remedies...
Search Results "Water Closet Clear Floor Space"
Commonly Searched Documents
-
Section A: Parking
-
11B-213.3.1 Toilet compartments
In addition to the compartments required to comply with Section 11B-604.8.1, where six or more toilet compartments are provided, or where the combination of urinals and water closets totals...
-
4.34.6.4(4)
(4) A clear floor space 30 in by 48 in (760 mm by 1220 mm) shall allow a forward approach to the counter....
- San Jamar C3165FBL Medium Pull-Type Water Cup Dispenser
- San Jamar C3165WH Medium Pull-Type Water Cup Dispenser
- San Jamar C3165TBL Medium Pull-Type Water Cup Dispenser
-
405.9.1 Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
-
305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space....
-
11B-604.9.6 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 _|Operation|_ and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the...
-
9.2.2(6)
(6) Where provided as part of an accessible unit, sleeping room, or suite, the following spaces shall be accessible and shall be on an accessible route: (a) the living area....
-
Car Controls [§407.4.6 and §407.4.7]
Car Controls [§407.4.6 and §407.4.7] If more than one car control panel is provided in a car, both must comply (except in existing cars where only 1 panel must comply). Car...
-
Error/Omission: Toilet rooms with 6 or more toilet stalls lack a 36" wide "ambulatory" toilet stall.
Requirement: 4.22.4, 4.23.4 Water Closets....
- San Jamar C4150SS Small Pull-Type Water Cup Dispenser
- San Jamar C4160WH Small Pull-Type Water Cup Dispenser
- San Jamar C4160TBL Small Pull-Type Water Cup Dispenser
-
If a property owner hits the 20% cost cap on path of travel improvements when installing charging stations, are there any other accessibility site retrofits that would still be required?
RESPONSE: EVCS required to be accessible by CBC Chapter 11B must have both, an accessible route to the facility entrance (see CBC Section 11B-812.5.1) and an accessible route from the vehicle space...
-
Low Energy Doors and Gates [§404.3]
Low Energy Doors and Gates [§404.3] Low energy doors and gates usually require activation by the user through a push plate or control and are often used in moderate traffic...
- SafePath: Sport Floor Reducers for ADA and Disability Access
-
§ 38.95(d) Mobility aid seating location
Spaces for persons who wish to remain in their wheelchairs or mobility aids shall have a minimum clear floor space 48 inches by 30 inches....
-
California: Toilet Grab Bars - Uneven height allowed?
Grab bars for water closets shall comply with Section 11B-609. Grab bars shall be provided on the side wall closest to the water closet and on the rear wall....
- Access Board: General Accessible Parking Requirements
-
POWDER ROOM
A room containing a water closet (toilet) and a lavatory, and which is not defined as a bathroom....
-
POWDER ROOM
A room containing a water closet (toilet) and a lavatory, and which is not defined as a bathroom....
-
EXHIBIT F ADA Maintenance Checklist
There must be sufficient clear floor space for approach and maneuvering room by a wheelchair. a....