Except as provided in R302.3.1 and R302.3.2, the continuous clear width of pedestrian access routes shall be 1.2 m (4.0 ft) minimum, exclusive of the width of the curb....
Search Results "Water Closet Clear Floor Space"
-
R302.3 Continuous Width
-
11B-306.2.4 Additional clearance
Space extending greater than 6 inches (152 mm) beyond the available knee clearance at 9 inches (229 mm) above the finish floor or ground shall not be considered toe clearance....
-
1132A.3, Item 4
A nominal 32-inch (813 mm) clear opening provided by a standard 6-foot wide (1829 mm) sliding patio door assembly is acceptable....
-
6.3(2)
(2) Each bedroom shall have adequate space to provide a maneuvering space that complies with 4.2.3. In rooms with 2 beds, it is preferable that this space be located between beds....
-
ADA Compliance BRIEF: Restriping Parking Spaces
U.S. Department of Justice Civil Rights Division Disability Rights Section
-
A4.26.2 Size and Spacing of Grab Bars and Handrails
This specification allows for alternate shapes of handrails as long as they allow an opposing grip similar to that provided by a circular section of 1‒1/4 in to 1‒1/2 in (32 mm to 38...
-
11B-1009.5.1 Transfer platform
Transfer platforms shall provide 19 inches (483 mm) minimum clear depth and 24 inches (610 mm) minimum clear width....
-
Shower Threshold
The Board retained the ½ inch threshold height since positioning for transfer to the seat of transfer showers can be aided where a close approach enables footrests to clear the threshold...
-
502.1 General
Car and van parking spaces shall comply with 502....
- SmartCells Flooring: Softer Anti-Fatigue Mats are NOT Better
-
502.1 General
Car and van parking spaces shall comply with 502....
-
Current Accessibility Guidelines That Apply to the Forest Service
Forest Service drinking fountains, toilet facilities, parking lots and spaces, cabins, and administrative buildings are among the components covered by ABAAS....
-
Dispersion Requirements
In the proposed rule, the Board posed several questions concerning the requirements for the dispersion of wheelchair spaces (which were located in section 802.6)....
-
11B-233.3.6 Graduate student and faculty housing at a place of education
facilities, including, but not limited to, the provisions in sections 233 and 809. 1) In sleeping rooms with more than 25 beds covered by this part, a minimum of 5% of the beds shall have clear...
-
11B-233.3.6 Graduate student and faculty housing at a place of education
facilities, including, but not limited to, the provisions in sections 233 and 809. 1) In sleeping rooms with more than 25 beds covered by this part, a minimum of 5% of the beds shall have clear...
-
11B-502.1 General
Car and van parking spaces shall comply with Section 11B-502....
-
106.5.13 Boat Launch Ramp
A sloped surface designed for launching and retrieving trailered boats and other water craft to and from a body of water....
-
1007.1 Accessible means of egress required
Accessible spaces shall be provided with not less than one accessible means of egress....
-
408.1 General
Where stationary ICT provides one or more display screens, at least one of each type of display screen shall be visible from a point located 40 inches (1015 mm) above the floor space where...
-
11B-302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3, 11B-409.4.3, 11B-410.4, 11B-810.5.3...
- Walk-A-Sured Roll-On Anti-Slip Safety Coating System
-
ETA Public Telephone Summary Chart and Survey Instructions
. [4.1.3(17)(a)] b. 1 per floor, when 1 bank is provided on this floor [4.1.3(17)(a)] c. 1 per bank, when 2 or more banks are provided on this floor....
- Caroma® USA H2 Zero Waterless Urinal Operation Video
-
306.3.1 General
Space under an element between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground shall be considered knee clearance and shall comply with 306.3....