modifications are necessary (§206.2.3.1) (or as needed to provide an accessible path of travel to an altered primary function area if not disproportionate to the cost (§202.4)), unless the building...
Search Results "State Building Code"
-
Vertical Access
-
1009.7.4 Stairways
Exception: The clear width of 48 inches (1220 mm) between handrails is not required at stairways serving buildings equipped throughout with an automatic sprinkler system installed in accordance...
-
Training
Within two (2) months after a computer based learning module is approved by the United States, and on an annual basis thereafter for the life of this Agreement, Blockbuster will provide...
-
DOT Memorandum: INFORMATION: Snow Removal on Sidewalks Constructed with Federal Funding
Section 116 requires a State DOT to maintain projects constructed with Federal-aid funding or enter into a maintenance agreement with the appropriate local official where such projects are...
-
C. Corporate ADA Contact Person, ADA Liaison, and ADA Grievance Procedure
Within sixty (60) days of the effective date of this Agreement, Atlantis will designate or hire a Corporate ADA Contact Person and identify that person to the United States. ...
-
ACTIONS TO BE TAKEN BY AURORA
Copies of such attendance logs shall be provided to the United States within ten days of any request for them and maintained for the duration of this Agreement....
-
VIII. REPORTING, MONITORING, ENFORCEMENT, AND OTHER MISCELLANEOUS PROVISIONS
) months after the Effective Date of this Consent Decree and every six (6) months thereafter throughout the term of this Consent Decree, QuikTrip shall submit to counsel for the United States...
-
Injunctive Relief
Establishment of ADA Complaint Procedure: Within 60 days, UPDC shall submit to the United States a proposed ADA Complaint Procedure, which will be subject to approval by the United States...
-
1007.1 Accessible means of egress required
In addition to the requirements of this chapter, means of egress, which provide access to, or egress from, buildings for persons with disabilities, shall also comply with the requirements...
-
F208.3.1 General
Parking spaces complying with 502 that serve a particular building or facility shall be located on the shortest accessible route from parking to an entrance complying with F206.4....
-
11B-206.4 Entrances
Where an alteration includes alterations to an entrance, and the building or facility has another entrance complying with 404 that is on an accessible route, the altered entrance shall not...
-
208.3.1 General
Parking spaces complying with 502 that serve a particular building or facility shall be located on the shortest accessible route from parking to an entrance complying with 206.4....
-
1007.3 Enclosed exit stairways
The area of refuge is not required at open stairways that are permitted by Section 1019.1 in buildings or facilities that are equipped throughout with an automatic sprinkler system installed...
-
1. Existing Facilities: Program Accessibility
When a service, program, or activity is located in a building that is not accessible, a small town can achieve program accessibility in several ways....
-
III−1.3000 Commercial facilities
The requirements of title III for new construction and alterations cover commercial facilities, which include nonresidential facilities, such as office buildings, factories, and warehouses...
-
1009.1 Accessible means of egress required
In addition to the requirements of this chapter, means of egress, which provide access to, or egress from, buildings for persons with disabilities, shall also comply with the requirements...
-
68.93. Complaints, Investigations, and Audits
A complaint may be filed against an owner if there is reason to believe that a building or facility is not in compliance with the Act, the rules, or the TAS....
-
Visual Alarms
Result: People who are deaf have no way of knowing that a building emergency has been declared while others who can hear are alerted by the audible alarm....
-
11B-206.4 Entrances
Where an alteration includes alterations to an entrance, and the building or facility has another entrance complying with 404 that is on an accessible route, the altered entrance shall not...
-
11B-206.4 Entrances
Where an alteration includes alterations to an entrance, and the building or facility has another entrance complying with 404 that is on an accessible route, the altered entrance shall not...
-
3. Maintenance of Accessible Features
those features that are necessary to provide access to services, programs, and activities -- including elevators and lifts, curb ramps at intersections, accessible parking spaces, ramps to building...
-
21. New construction
If an alteration is undertaken to a portion of a building the accessibility of which could be improved by the manner in which the alteration is carried out, the alteration must be made in...
-
A. Fire Alarms
If the building has an audible fire alarm system, do each of the following rooms in the hotel have a visual alarm strobe light mounted on the wall at 80" above the floor to alert deaf persons...
-
II-3.10000 Maintenance of accessible features
ILLUSTRATION 1: It would be a violation for a building manager of a three-story building to turn off the only passenger elevator in order to save energy during the hours when the building...