Standards § 9.3 may be achieved by providing either (1) visual alarms connected to the building emergency alarm system, and visual notification devices for incoming telephone calls and door...
Search Results "Side-Opening Door"
Commonly Searched Documents
-
15(e)
-
11B-221.1 General
At least five percent of aisle seats (but not less than one) are required to either have no armrest on the aisle side or to have a removable or folding armrest on the aisle side....
-
802.1.3 Depth
Where a wheelchair space can be entered only from the side, the wheelchair space shall be 60 inches (1525 mm) deep minimum....
-
7. Grab Bars
Are there two horizontal grab bars (one high/one low) along the side of the tub that are at least 24" long for stabilization and aid in transfer from a wheelchair to the fixed tub seat -...
-
6.3(3)
(3) Each two-bed room shall have a minimum clear floor space of 42 in (1065 mm), preferably 48 in (1220 mm), between the foot of the bed and the wall; 36 in (915 mm) between the side of...
-
M303.2.3 Depth
Where wheelchair spaces can be entered only from the side, the wheelchair space shall be 60 inches (1525 mm) deep minimum....
-
M303.2.6 Edge Protection
provided on a platform raised more than 1 ½ inches (38 mm) in height, edge protection 2 inches (51 mm) high minimum measured from the surface of the platform shall be provided on each side...
-
Aisle Stairs and Ramps in Assembly Areas
Section 4.8.5 of the 1991 Standards exempts aisle ramps that are part of an accessible route from providing handrails on the side adjacent to seating....
-
11B-704.4.1 Height
accessible telephone because the required 34 inches (865 mm) minimum keypad height can causes the highest operable part of the telephone, usually the coin slot, to exceed the maximum permitted side...
-
Tools and Documentation
The following tools are needed for the 2016 Checklist: a metal tape measure at least 20 feet long a digital level or a bubble level that is at least 24 inches long a door pressure...
-
§ 36.207(b)
the residence covered under paragraph (a) of this section extends to those elements used to enter the place of public accommodation, including the homeowner´s front sidewalk, if any, the door...
-
Special Technical Provisions for Alterations to Existing Buildings and Facilities [4.1.6(3)]
Special provisions also address stairs, elevators, doors, toilet rooms, assembly areas, platform lifts, and dressing rooms....
-
§ 38.53(d)(2) Exception
At key stations, the horizontal gap between at least one door of each such vehicle and the platform shall be no greater than 3 inches....
-
§ 38.73(d)(2) Exception
At key stations, the horizontal gap between at least one door of each such vehicle and the platform shall be no greater than 3 inches....
-
1133A.6 Kitchen sink faucet controls
Self-closing valves are allowed if the faucet remains open for at least 10 seconds....
-
1134A.8, Item 7
Self-closing valves are allowed if the faucet remains open for at least 10 seconds....
-
1134A.8, Item 7
Self-closing valves are allowed if the faucet remains open for at least 10 seconds....
-
1009.6.4 Separation
Areas of refuge in outdoor facilities where exit access is essentially open to the outside....
-
EXTREME WEATHER
Extreme Heat: Opens cooling centers to help prevent heat-related illness or death....
-
604.3.2 Overlap
When the door to the toilet room is placed directly in front of the water closet, the water closet cannot overlap the required maneuvering clearance for the door inside the room....
- Magnuson Group VOICI Magazine Racks
-
804.2.2 U-Shaped
In U-shaped kitchens enclosed on three contiguous sides, clearance between all opposing base cabinets, counter tops, appliances, or walls within kitchen work areas shall be 60 inches (1525...
-
R304.5.1 Width
If provided, flared sides of curb ramp runs and blended transitions shall be located outside the width of the curb ramp run or blended transition....
-
608.3.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....