- Spectrum Aquatics Aspen Pool Lift
-
ASME: ADA Standard Section 105.2.2
Section 105.2.2 of the ADA Standards cover references to the American Society of Mechanical Engineers (ASME) standards.
-
H17
Is at least 9 inches of toe clearance provided under the front wall and at least one side wall of the toilet stall? [ADA Standards § 4.17.4] Yes No...
-
305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space....
-
4.9.4(1)
(1) Handrails shall be continuous along both sides of stairs. The inside handrail on switchback or dogleg stairs shall always be continuous (see Fig. 19(a) and (b))....
-
Handrails [4.9.4]
Continuous handrails are required along both sides of stairs. A center rail is not specified for wide stairways by ADAAG but may be required by local building or life safety codes....
-
§ 38.23(c)(4) Ramp barriers
Each side of the ramp shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off....
-
Are stairway chairlifts permitted?
Chairlifts require transfer to a fixed seat from wheeled mobility aids and thus are not independently usable....
-
TTY Shelf: ADA Standard Section 704.5
The telephone handset shall be capable of being placed flush on the surface of the shelf....
-
11B-704.5 TTY shelf
The telephone handset shall be capable of being placed flush on the surface of the shelf....
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
11B-308.4 Suggested reach ranges for children
These dimensions apply to either forward or side reaches....
-
907.2.6.1 Group I-2
Such detectors shall provide a visual display on the corridor side of each patient room and shall provide an audible and visual alarm at the nursing station attending each room....
-
Safe Harbor – Construction Prior to March 15, 2012
For example, the 1991 Standards allow 54 inches maximum for a side reach range to a control such as the operating part of a paper towel dispenser....
-
Storage [9.2.2(4)]
Clear floor space for either a forward or side approach is allowed....
-
11B-502.6.4.2
The centerline of the International Symbol of Accessibility shall be a maximum of 6 inches (152 mm) from the centerline of the parking space, its sides parallel to the length of the parking...
-
11B-502.6.4.2
The centerline of the International Symbol of Accessibility shall be a maximum of 6 inches (152 mm) from the centerline of the parking space, its sides parallel to the length of the parking...
-
11B-308.4 Suggested reach ranges for children
These dimensions apply to either forward or side reaches....
-
1117B.5.7
Where permanent identification signs are provided for rooms and spaces, signs shall be installed on the wall adjacent to the latch side of the door....
-
R405.2.1 General
Space under an element between the finish surface and 230 mm (9 in) above the finish surface shall be considered toe clearance and shall comply with R405.2....
-
1008.2.5.3.2 Handrail Height
The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface....
- Mockett DH3/BB Square Door Handle Installation Video
-
407.3.1 Identification (Section-by-Section Analysis)
It also would require key surfaces outside active areas of display screens to be raised above their surrounding surfaces....
-
705.1.3 Contrast
Detectable warning surfaces shall contrast visually with adjacent walking surfaces either light-on-dark, or dark-on-light. Figure 705.1 Size and Spacing of Truncated Domes...