Design and the Architectural Barriers Act (ABA) Accessibility Standards require newly constructed playgrounds and those existing playgrounds that are altered to comply with a series of technical...
Search Results "Feasibility (Technical, Infeasible, Structural, Maximum Extent)"
-
I. Introduction to the Study
-
[2010 ADAS] 105.2.3 ASTM
It defines the use zone, which is the ground area beneath and immediately adjacent to a play structure or play equipment designed for unrestricted circulation around the equipment and on...
-
ASTM
It defines the use zone, which is the ground area beneath and immediately adjacent to a play structure or play equipment designed for unrestricted circulation around the equipment and on...
- Cavity Sliders USA Inc. CL100 ADA Privacy Lever Lock for Pocket Doors
-
11B-604.6 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except they shall be located 44 inches (1118 mm) maximum above the floor....
-
11B-809.2.2 Turning space
Exception: Turning space shall not be required in exterior spaces 30 inches (762 mm) maximum in depth or width. Advisory 11B-809.2.2 Turning space....
-
11B-604.6 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except they shall be located 44 inches (1118 mm) maximum above the floor....
-
11B-809.2.2 Turning space
Exception: Turning space shall not be required in exterior spaces 30 inches (762 mm) maximum in depth or width. Advisory 11B-809.2.2 Turning space....
-
F. Electronic and information technology
On March 22, 2010, the Access Board published an ANPRM seeking public comment on its plans to amend the 2004 ADA/ABA Accessibility Guidelines to include technical guidelines for self-service...
-
Getting to the Water—Beach Access Routes
Removable beach access routes are not required to comply with the slope and resting interval technical requirements....
-
Wheelchair Spaces (M303.2)
M303.2 includes technical criteria for orientation, width, depth, and knee and toe clearance at wheelchair spaces....
- DOE Resource: Identifying and Treating Attention Deficit Hyperactivity Disorder: A Resource for School and Home
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
Cross Slope
Cross Slope The cross slopes of gangways, transition plates and floating piers that are part of an accessible route must be designed and constructed not to exceed a maximum of 2 percent...
-
Dispersion
To provide anglers with disabilities similar opportunities, the accessible 34-inch maximum railing must be located in a variety of places on the pier or platform to offer a variety of locations...
-
403.5.1 Clear Width
EXCEPTION: The clear width shall be permitted to be reduced to 32 inches (815 mm) minimum for a length of 24 inches (610 mm) maximum provided that reduced width segments are separated by...
-
407.4.8.2.1 Signal Type
EXCEPTION: For elevators other than destination-oriented elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz maximum...
-
Toilet Rooms-Banquet Area
The force required to push or pull open the doors to the women's and men's toilet rooms designated as accessible is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf...
-
Toilet Rooms North (Celebrity Spies)–Men [sic]
The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). ee....
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
1009.5.4 Transfer Steps
Transfer step height shall be 8 inches (205 mm) maximum....
-
Passing Spaces (R302.4) (Section-by-Section Analysis)
Section-by-Section Analysis) Where the clear width of pedestrian access routes is less than 1.5 meters (5 feet), passing spaces must be provided at intervals of 61 meters (200 feet) maximum...
-
R407.2 Running Slope
Ramp runs shall have a running slope between 5 percent minimum and 8.3 percent maximum. Advisory R407.2 Running Slope....
-
608.3.3 Alternate Roll-In Type Shower Compartments
Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls. Figure 608.3.3 Grab Bars for Alternate Roll-In Type Showers...