Re: DSA Drawing 11B-406-1C Curb Ramp Adjoining a Parking Access Aisle next to a Curb and Gutter (2016 CBC)
If the slope of the gutter is greater than 1:48, can they merely show it outside of the required 18' deep accessible parking space and access aisle?...
-
1. Standing Supports
The MDE Advisory Committee addressed the issue of standing supports for mammography equipment as well as that of standing supports for wheelchair spaces with raised platforms....
- Seton Optima Men Restroom Sign
- Seton Custom Sized Braille Signs L2852
-
407.4.8.1.3 Floor Arrival
As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate....
-
407.4.8.1.3 Floor Arrival
As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate....
- Willoughby Industries ASETW1490FM Ligature-Resistant Floor Mounted Blowout Series Water Closet
-
SECTION 1013 EXIT SIGNS
[See subsections ...]
-
11B-216.9.1 Identification signs
Public TTYs shall be identified by the International Symbol of TTY complying with Section 11B-703.7.2.2.
-
11B-216.9.1 Identification signs
Public TTYs shall be identified by the International Symbol of TTY complying with Section 11B-703.7.2.2.
-
SECTION 1013 EXIT SIGNS
[See subsections ...]
- Seton Directional Entrance Sign - Left Arrow
-
Additional Parking Spaces for Residents: ADA Standard Section 208.2.3.2
Section 208.2.3.2 covers scoping requirements in the current ADA Standards for additional parking spaces for residents.
-
703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
Maps/floor plans
Maps/floor plans: f....
-
11B-224.7 Housing at a place of education
Exceptions: Kitchens within housing units containing accessible sleeping rooms with mobility features (including suites and clustered sleeping rooms) or on floors containing accessible...
-
M303.3.3.2 Cross Slope
The cross slope of ramp runs shall not be steeper than 1:48.
-
M303.3.3 Ramped
Changes in level greater than ½ inch (13 mm) high shall be ramped and shall comply with M303.3.3.
-
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height. Edge protection is not required on platforms 1 ½ inches or less in height.
-
5.8.1.2.2 Single Ramped Entry - Edge Protection on the Platform and Platform Sides Recommendations
5.8.1.2.2 Single Ramped Entry - Edge Protection on the Platform and Platform Sides Recommendations The Committee recommends a two-inch high edge protection on the back of the...
-
5.8.1.2.1 Ramped Entry Slope
5.8.1.2.1 Ramped Entry Slope. Raised platforms should have a ramp with slopes that do not exceed the following: Rise 0 to 1 ½ inches – 1:2 Slope Rise >1 ½ to 2 ½ inches – 1:8...
-
5.8.1.2.3 Double Ramped Entry – Edge Protection on the Platform Sides
5.8.1.2.3 Double Ramped Entry – Edge Protection on the Platform Sides. A minimum 2 inch high edge protection must be provided on both sides of the platform for double ramped entry...
-
5.8.1.2.2 Single Ramped Entry – Edge Protection on the Platform and Platform Sides
5.8.1.2.2 Single Ramped Entry – Edge Protection on the Platform and Platform Sides. A 2 inch high edge protection must be provided on the back of the platform, opposite the entry...