Can back doors and freight elevators be used to satisfy the program accessibility requirement?
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
F. Check-In Areas
This may be a part of the reception counter that is no higher than 36 inches above the floor, a folding shelf or an adjacent table, or a clip board....
-
217.4 TTYs
Separate requirements are provided based on the number of public pay telephones provided at a bank of telephones, within a floor, a building, or on a site....
-
904.4 Sales and Service Counters
of the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with 904.4.1 provided that the required clear floor...
-
4.10.14* Emergency Communications
The highest operable part of a two-way communication system shall be a maximum of 48 in (1220 mm) from the floor of the car....
-
Kitchen Electrical/Lighting/Mechanical
Low voltage lighting saves energy Low voltage lights also improves visual acuity in cabinets Hot water floor heating to keep heat low in the room for children, shorter people...
-
Accessible Route [9.2.2(2)]
Recommendation: ADAAG does not address furniture, but it is recommended that where dressers are provided, clear floor space should be provided so that people using wheelchairs can access...
-
Scoping [4.1.3(4)]
Compliance is required where stairs are the only connection between two levels, such as between floors in buildings without elevators....
-
Room Dimensions
For single-user toilet rooms, key considerations include the configuration of water closets and lavatories, clear floor spaces required at fixtures, turning space, the location and swing...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Side Approach Power Chair
chair users represented as the percentage of users able to retrieve and place a 5 lb object on a target shelf in the lateral or sideways reach direction for a given (a) height from the floor...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Side Approach Scooter
scooter users represented as the percentage of users able to retrieve and place a 5 lb object on a target shelf in the lateral or sideways reach direction for a given (a) height from the floor...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Side Approach Manual Wheelchair
chair users represented as the percentage of users able to retrieve and place a 5 lb object on a target shelf in the lateral or sideways reach direction for a given (a) height from the floor...
-
9.5 LOCKER ROOMS
., intended for use by people in wheelchairs shall be located no higher than 48 in (1220 mm) above the finished floor....
-
Signs [ADA Standards §216, §703]
Tactile signs must include compliant raised characters and braille characters and be located at doors 48” to 60” above the floor or ground (§703.2)....
-
4) Entrances
UFAS: At least one principal entrance at each grade floor level must be accessible....
-
11B-233.3.4.3 Alterations to residential dwelling units with adaptable features
Exception: Where any portion of a building’s exterior is preserved, but the interior of the building is removed, including all structural portions of floors and ceilings and a new building...
-
Chapter 7 Addendum 2: The ADA and Emergency Shelters: Access for All in Emergencies and Disasters
financial and administrative burdens.2 This Addendum discusses some of the key issues that emergency managers and shelter operators need to address in order to comply with the ADA when they plan...
-
382.67 What is the requirement for priority space in the cabin to store a passenger’s wheelchair?
Where a carrier plans to use a closet or other storage area to comply with this requirement, we emphasize that in saying priority storage we mean that the space for a wheelchair trumps other...
-
D. Notification – Alerting the Public to an Emergency
The emergency management plan should identify the steps that will be taken and the resources that will be used to ensure that emergency notifications will be accessible to all....
-
Scenario 7 – Reevaluations and FAPE
Salim is a student with a disability and he has a Section 504 plan. At the start of the spring semester, he received an out-of-school suspension for 12 consecutive school days....
-
Examples of Implementation Methods
one or two staff members as department ADA coordinators to work with citywide coordinator. 3.Task force reviewed regulations, identified preliminary issues and developed review plan...
-
Updates and Other Pocket Guides
For ADA survey and compliance tools that will simplify your field measurement process and plan reviews, http://www.adasurveytools.com/ has a growing collection of templates and tools you...
-
Using the Polling Place Checklist
All answers and notes should be recorded on the checklist for use later in the planning process....