The slope of the clear floor or ground space required by section 4.2.6 shall not exceed 1:48 (2 percent) in any direction. Exception....
Search Results "9-1-1 Service"
Commonly Searched Documents
-
4.2.8 Slope
-
4.6.5 Slope
The slope of the clear floor or ground space required by section 4.6.4 shall not exceed 1:48 (2 percent) in any direction. Exception....
-
4.7.3 Slope
The slope of the clear floor or ground spaces required by section 4.0 shall not exceed 1:48 (2 percent) in any direction. Exception....
-
1.1.3
1.1.3 A maximum overall design running slope for exterior accessible surfaces (other than ramps), such as sidewalks, of 4% (approximately 1:25) is recommended....
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
Alterations: ADA Standard Section 202.3
Section 202.3 covers the most current requirements for alterations in existing building and facilities.
-
11B-206.2.8 Employee work areas
Exceptions: 1. Reserved. [2010 ADA Standards] 1....
-
11B-603.2.3 Door swing
[2010 ADA Standards] 1....
-
2.2 Evidence of Physical Accessibility Barriers
Only 22 (9%) reported use of either a height-adjustable examination table or a lift for transfer....
- Pilot Rock SQT3-4 Series Square Portable Table - Using Expanded or Perforated Steel
-
Metal measuring tapes
Most tapes used in construction are graduated in units of 1/16 inch or millimeters....
-
11B-609.3 Spacing
The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
-
Swinging Doors and Gates: ADA Standard Section 404.2.4.1
Section 404.2.4.1 covers the current ADA Standards for maneuvering clearances at swinging doors and gates.
-
Door and Gate Surfaces: ADA Standard Section 404.2.10
Section 404.2.10 covers the current ADA Standards for door and gate surfaces on manual doors and gates.
-
Minimum Number: ADA Standard Section 234.3
Section 234.3 covers scoping requirements in the current ADA Standards for the minimum number of wheelchair spaces required at amusement rides.
-
Residential Dwelling Units for Sale: ADA Standard Section 233.3.2
Section 233.3.2 covers scoping requirements in the current ADA Standards for residential dwelling units for sale.
-
11B-608.3 Grab bars
Exceptions: 1. Reserved. [2010 ADA Standards] 1....
-
11B-410.8 Restriction sign
For lifts with a signed installation contract before May 1, 2008: CCR, Title 8, Section 3094 provides safety regulations for Vertical Platform (Wheelchair) Lifts....
-
1010.2.13.1 Delayed egress locking system
Sign lettering shall be at least 1 inch (25 mm) in height and shall have a stroke of not less than 1/8 inch (3.2 mm). 6.4....
-
Suspicious Minds Ramp
The handrail of the ramp leading to the exhibits is not at the required distance of 1 1/2" from the wall. See Standards § 4.8.5(3)....
-
NEW CONSTRUCTION AND ALTERATIONS {35.151}
ALTERATIONS {35.151} New Construction Shall be designed and constructed to be readily accessible to and usable by individuals with disabilities when bids are invited after 1-...
-
5.3.2.3 Slope
The slope of the turning space and clear floor or ground space surface shall not be steeper than 1:48 (2 percent) in all directions....
-
4.1.5 Slope
The slope of the surface of the clear floor or ground space around a picnic table shall not exceed 1:48 (2 percent) in any direction. Exception....