General Information For doors 1-3⁄8" (35mm) to 1-3⁄4" (44mm) thick standard 2-3/4" (70mm) backset standard; Optional: 2-3/8" (60mm); see quick codes; page 9 Curved lip T-Strike...
Search Results "1991 Standards"
Commonly Searched Documents
- Corbin Russwin Inc. TL3700 Series of tubular locks
-
Auditorium accessible seating
Front or back approach from an accessible route requires a floor area of 36” x 48” for the wheelchair (ref: 2010 ADA Standards 802.1.3). ...
- Kompan, Inc. NAT204 - Tacoma Bench
- Yale 4700LN Series Grade 1 Cylindrical Locks
- Mansfield Lavatory Grande Isle 2018HBNS
- Activar Hiawatha DBP004 Door Bottom Edge with Kickplate for 1-3/4” Door
- Sargent 8900 Mortise Lock Exit Device
- Allegion Schlage S-Series Mechanical Locks with Tubular Interconnect
- TownSteel CE/CEC Series, Grade 1, Heavy Duty Cylindrical Locks
-
Re: 404.2.6 Doors in Series and Gates in Series
What is the purpose of the doors in series requirement and how should it be applied in configurations other than those shown in the Figures in the Standards?...
-
411.1 General (Section-by-Section Analysis)
This proposal largely corresponds to existing 508 Standards §§ 1194.23(j) and 1194.24(a), and existing 255 Guidelines § 1193.37, though it differs in a few notable respects....
-
Feature 4 - Routes to the Meeting Space
ADA Standards for Accessible Design | Temporary Barrier Removal Suggestions for Accessible Features It is important to note that people who are blind or have low vision may use all routes...
-
2. State and Local Laws
particular job or profession because of a health or safety risk, the employer still must assess whether a particular individual would pose a "direct threat" to health or safety under the ADA standard...
-
Medical facilities
(3), which states that “[w]ith respect to medical and long-term care facilities in jails, prisons, and other detention and correctional facilities, public entities shall apply the 2010 Standards...
-
Introduction
The ADA uses different standards than the military and the Department of Veterans Affairs in determining disability status....
-
Water Closet Clear Floor Space
In addition, the new ANSI A117.1 standard includes a reference to sanitary napkin disposal units. Response....
-
PART 3: ACCESSIBLE EXAMINATION ROOMS
New and altered examination rooms must meet requirements of the ADA Standards for Accessible Design....
-
11B-103 Equivalent facilitation
ETA Editor's Note The acceptance of an Equivalent Facilitation argument by a Local Building Official or other Authority Having Jurisdiction does not warrant that the standards for Equivalent...
-
Interim Segway® Personal Transporter Policy
GSA will continue to comply with the building accessibility standards identified in 41 C.F.R. § 102-76.65....
-
Grab Bar Cross Sections
objects above has been changed from 15 inches to 12 inches (609.3), consistent with specifications for toilet paper dispensers included in the proposed rule (604.7) and the ANSI A117.1‒2003 standard...
-
206.3 Location
vertical interior circulation must be in the same area as stairs and escalators, not isolated in the back of the facility Note to Reader: The Department of Transportation’s ADA standards...
-
1. LEGAL ISSUES
discussed the term "conventional building industry tolerances" as follows: "What is an acceptable ‘dimensional tolerance’ obviously will vary, depending in part upon the purpose for the standard...
-
221.2.2 Integration
spaces and companion seats provided in specialty seating areas shall be included in, rather than in addition to, wheelchair space requirements set forth in Table 221.2.1.1 in the 2010 Standards...
-
Technical Memorandum TM 2013-12 Number of Accessible Elements and Spaces
TM 2013-12 Number of Accessible Elements and Spaces Effective Date: June 1, 2013 2012 TAS Reference: 201.1 In accordance with TAS 201.1, the standards must be applied to...