1008.2.4.1 Ground Level
In play areas less than 1000 square feet (93 m2), the clear width of accessible routes shall be permitted to be 44 inches (1120 mm) minimum, if at least one turning space complying with...
-
1008.2.4.1 Ground Level
In play areas less than 1000 square feet (93 m2), the clear width of accessible routes shall be permitted to be 44 inches (1120 mm) minimum, if at least one turning space complying with...
-
1008.2.4.1 Ground Level
In play areas less than 1000 square feet (93 m²), the clear width of accessible routes shall be permitted to be 44 inches (1120 mm) minimum, if at least one turning space complying with...
-
11B-1008.2.4.1 Ground level
In play areas less than 1000 square feet (93 m2), the clear width of accessible routes shall be permitted to be 44 inches (1118 mm) minimum, if at least one turning space complying with...
-
11B-1008.2.4.1 Ground level
In play areas less than 1000 square feet (93 m2), the clear width of accessible routes shall be permitted to be 44 inches (1118 mm) minimum, if at least one turning space complying with...
-
11B-1008.2.4.1 Ground level
Exceptions: In play areas less than 1000 square feet (93 m2), the clear width of accessible routes shall be permitted to be 44 inches (1118 mm) minimum, if at least one turning space...
-
1008.4.1 Turning Space
At least one turning space complying with 304 shall be provided on the same level as play components....
-
1008.4.1 Turning Space
At least one turning space complying with 304 shall be provided on the same level as play components....
-
11B-1008.4.1 Turning space
At least one turning space complying with Section 11B-304 shall be provided on the same level as play components....
-
11B-1008.4.1 Turning space
At least one turning space complying with Section 11B-304 shall be provided on the same level as play components....
-
11B-1008.4.1 Turning space
At least one turning space complying with Section 11B-304 shall be provided on the same level as play components....
-
1008.4.1 Turning Space
At least one turning space complying with 304 shall be provided on the same level as play components....
-
Accessibility: ADA Standard Section 1008.2.6.1
Ground surfaces shall comply with ASTM F 1951 (incorporated by reference, see “Referenced Standards” in Chapter 1). Ground surfaces shall be inspected and maintained regularly and...
-
15. When are "path of travel" obligations triggered?
For example, an alteration is planned for a portion of an existing composite play structure....
-
11B-1008.2.6 Ground surfaces
The type of surface material selected and play area use levels will determine the frequency of inspection and maintenance activities. ◼...
-
GameTime Roller Table
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Kompan, Inc. M143P - Albatross Seesaw
Requires the Premium User plan or above. (Login or upgrade your account!)
-
GameTime Bongos
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Kompan, Inc. Solitaires Spinners - GXY8019 - Argo
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Kompan, Inc. Spring Riders M175P - Water Lilies
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Kompan, Inc. Spring Riders - M128P - Daisy
Requires the Premium User plan or above. (Login or upgrade your account!)
-
GameTime Merry-Go-All Plan
Requires the Premium User plan or above. (Login or upgrade your account!)