Section 604.3.2 covers the current ADA Standards for overlapping clearances in the water closet clear floor space.
Search Results "Space Limitation"
Commonly Searched Documents
- 
    
  
  Overlap: ADA Standard Section 604.3.2
  
- 
    
  
  11B-206.4.5 Tenant spaces
  [2010 ADA Standards] 206.4.5 Tenant Spaces. At least one accessible entrance to each tenancy in a facility shall comply with 404.... 
- 
    
  
  11B-406.3.2 Turning space
  A turning space 48 inches (1219 mm) minimum by 48 inches (1219 mm) minimum shall be provided at the bottom of the curb ramp.... 
- 
    
  
  11B-703.2.7 Character spacing
  Character spacing shall be measured between the two closest points of adjacent raised characters within a message, excluding word spaces.... 
- 
    
  
  Clear Floor Space
  The minimum unobstructed floor or ground space required to accommodate a single, stationary wheelchair and occupant.... 
- 
    
  
  Space Needs
  and 2) the physical locations of these spaces relative to the first platform.... 
- 
    
  
  Clear Floor or Ground Space [§305]
  Clear Floor or Ground Space [§305] Sufficient clear floor or ground space is required at accessible controls, operable parts, drinking fountains, lavatories and sinks, ATMs and fare machines... 
- 
    
  
  WHEELCHAIR SPACE
  WHEELCHAIR SPACE. A space for a single wheelchair and its occupant.... 
- 
    
  
  Wheelchair Space
  Wheelchair Space. Space for a single wheelchair and its occupant.... 
- 
    
  
  ACCESSIBLE SPACE
  ACCESSIBLE SPACE. [DSA-AC] A space that complies with the accessibility provisions of this code.... 
- 
    
  
  11B-813.2.9 Overlap
  Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap.... 
- 
    
  
  Appropriate clear floor space
  Appropriate clear floor space (shown by dashed lines) is needed adjacent to each cell feature (see page 1 diagrams on clear floor space).... 
- 
    
  
  11B-304 Turning space
  [See subsections ...] 
- 
    
  
  304.3.2 T-Shaped Space
  The turning space shall be a T-shaped space within a 60 inch (1525 mm) square minimum with arms and base 36 inches (915 mm) wide minimum.... 
- 
    
  
  OCCUPIABLE SPACE
  OCCUPIABLE SPACE. ... 
- 
    
  
  11B-804.3.1 Clear floor or ground space
  A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided.... 
- 
    
  
  11B-602.2 Clear floor space
  Units shall have a clear floor or ground space complying with Section 11B-305 positioned for a forward approach and centered on the unit.... 
- 
    
  
  11B-603.2.1 Turning space
  Turning space complying with Section 11B-304 shall be provided within the room.... 
- 
    
  
  11B-612.3 Turning space
  A turning space complying with Section 11B-304 shall be provided within saunas and steam rooms.... 
- 
    
  
  11B-813.2.8 Turning space
  Turning space complying with Section 11B-304 shall be provided within adult changing facilities.... 
- 
    
  
  Space
  A definable area, such as a room, toilet room, hall, assembly area, entrance, storage room, alcove, courtyard, or lobby. 
- 
    
  
  Space
  A definable area, e.g., room, toilet room, hall, assembly area, entrance, storage room, alcove, courtyard, or lobby. 
- 
    
  
  SPACE
  A definable area, e.g., toilet room, hall, assembly area, entrance, storage room, alcove, courtyard, or lobby. 
- 
    
  
  SPACE
  A definable area, such as a room, toilet room, hall, assembly area, entrance, storage room, alcove, courtyard, or lobby. 
