[See subsections ...]
Search Results "Shower Compartment"
Commonly Searched Documents
-
A4.23 Bathrooms, Bathing Facilities, and Shower Rooms
-
A4.23 BATHROOMS, BATHING FACILITIES, AND SHOWER ROOMS
[See subsections ...]
-
4.23 BATHROOMS, BATHING FACILITIES, AND SHOWER ROOMS
[See subsections ...]
-
4.21.4 Grab Bars
Grab bars complying with 4.26 shall be provided as shown in Fig. 37.
-
Error/Omission: Adequate maneuvering clearance is not provided at doors, including doors to accessible toilet stalls.
Error/Omission: Adequate maneuvering clearance is not provided at doors, including doors to accessible toilet stalls. Result: A person using a wheelchair cannot open the...
-
9. Faucet Controls
Do roll-in showers have faucet controls that are easily operable with one hand (i.e.: levers, wrist blades, single arm, etc.) without tight grasping, pinching or twisting of the wrist?...
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
1e
Do all small showers have faucet controls that are easily operable with one hand (i.e.: levers, wrist blades, single arm, etc.) without tight grasping, pinching or twisting of the wrist?...
-
Example of a Single-User Bathroom (with Roll-in Shower)
Example of a Single-User Bathroom (with Roll-in Shower) Clear space required at any fixture can overlap required clear floor spaces, turning space, and door maneuvering space....
-
11B-610 Seats
[See subsections ...]
-
1607A.8.2 Grab bars, shower seats and dressing room bench seats
1607A.8.2 Grab bars, shower seats and dressing room bench seats....
-
604.9.1 Location
side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment...
-
604.9.1 Location
side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment...
-
604.9.1 Location
side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment...
-
11B-604.9.1 Location
side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment...
-
11B-604.9.1 Location
side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment...
-
1607.8.2 Grab bars, shower seats and dressing room bench seats
Grab bars, shower seats and dressing room bench seat systems shall be designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab...
-
1607.8.2 Grab bars, shower seats and dressing room bench seats
Grab bars, shower seats and dressing room bench seat systems shall be designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab...
-
1607.8.2 Grab bars, shower seats and dressing room bench seats
Grab bars, shower seats and dressing room bench seat systems shall be designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab...
-
607.6 Shower Spray Unit and Water
607.6 Shower Spray Unit and Water....
-
11B-604.9.1 Location
side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment...
-
H23
H23. Is the door to the toilet stall located diagonally opposite, not directly in front of, the toilet or on the opposite side wall from the wall with the long grab bar? [ADA...
-
607.6 Shower Spray Unit and Water
A shower spray unit with a hose 59 inches (1500 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
607.6 Shower Spray Unit and Water
A shower spray unit with a hose 59 inches (1500 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....