Where food or drink is served at counters exceeding 34 in (865 mm) in height for consumption by customers seated on stools or standing at the counter, a portion of the main counter...
Search Results "Salad Bar"
Commonly Searched Documents
- 
    
  
  5.2 Counters and Bars
  
- Pressalit Care PLUS Support Arm Height and Sideways Adjustable Swing Grab Bar
- Pressalit Care VALUE Support Arm Fixed Height Swing Grab Bar with Leg
- 
    
  
  Wall furr-out to support a grab bar when toilet is too far from the side wall
  Here's a good example of one solution for a water closet that's too far from the adjacent side wall. Sometimes this solution is easier than moving the fixture when an offset flange... 
- Bradley Grab Bar 29" Swing Up, Integral Toilet Tissue Holder 8370-103
- 
    
  
  11B-212.1 General
  Where provided, kitchens, kitchenettes, wet bars and sinks shall comply with Section 11B-212. [2010 ADA Standards] 212.1 General.... 
- 
    
  
  11B-809.10.6.4 Reinforcement for grab bars
  Reinforcement for grabs bars shall comply with the following: Continuous reinforcement shall be installed in the walls of showers 30 inches (762 mm) maximum to 38 inches (965 mm) minimum... 
- 
    
  
  11B-212.1 General  
  Where provided, kitchens, kitchenettes, wet bars and sinks shall comply with Section 11B-212. ... 
- 
    
  
  11B-212.1 General
  Where provided, kitchens, kitchenettes, wet bars and sinks shall comply with Section 11B-212. ... 
- 
    
  
  11B-809.10.8.7 Mirrors and towel bars
  Where towel bars are provided they shall be installed 40 inches (1016 mm) maximum above the finish floor to the top of the bar.... 
- 
    
  
  609.2.1 Circular Cross Section
  Grab bars with circular cross sections shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum.... 
- 
    
  
  1g
  Is there a horizontal grab bar on the wall opposite the seat as shown in Figure 37(a) above?... 
- 
    
  
  11B-609.2.1 Circular cross section
  Grab bars with circular cross sections shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum.... 
- 
    
  
  11B-609.2.1 Circular cross section
  Grab bars with circular cross sections shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum.... 
- 
    
  
  Dispensers: ADA Standard Section 604.9.6
  Section 604.9.5 covers the current ADA Standards for dispensers in children's use toilet compartments. 
- 
    
  
  609.2.1 Circular Cross Section
  Grab bars with circular cross sections shall have an outside diameter of 1 1/4 inches (32 mm) minimum and 2 inches (51 mm) maximum.... 
- 
    
  
  609.2.1 Circular Cross Section
  Grab bars with circular cross sections shall have an outside diameter of 1 1/4 inches (32 mm) minimum and 2 inches (51 mm) maximum.... 
- 
    
  
  609.2.1 Circular Cross Section
  Grab bars with circular cross sections shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum.... 
- 
    
  
  4.26.4 Eliminating Hazards
  A handrail or grab bar and any wall or other surface adjacent to it shall be free of any sharp or abrasive elements. Edges shall have a minimum radius of 1/8 in (3.2 mm).... 
- 
    
  
  4.26.4 ELIMINATING HAZARDS
  A handrail or grab bar and any wall or other surface adjacent to it shall be free of any sharp or abrasive elements. Edges shall have a minimum radius of 1/8 in (3.2 mm).... 
- 
    
  
  11B-604.9.6 Dispensers
  There shall be a clearance of 1½ inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow.... 
- 
    
  
  11B-609.2.1 Circular cross section
  Grab bars with circular cross sections shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum.... 
- 
    
  
  1f
  Is there a horizontal grab bar on the wall alongside the shower seat (but not behind the shower seat) for stabilization and to aid in transfer from a wheelchair to the folding shower seat... 
- 
    
  
  11B-226.3 Dining surfaces exceeding 34 inches in height
  Where food or drink is served for consumption at a counter exceeding 34 inches (864 mm) in height, a portion of the main counter 60 inches (1525 mm) minimum in length shall be... 