Section 304.2 covers the current ADA Standards for the ground surfaces of a turning space.
Search Results "Running Slope"
Commonly Searched Documents
-
Floor or Ground Surfaces: ADA Standard Section 304.2
-
11B-304.2 Floor or ground surfaces
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved. Advisory 11B-304.2 Floor or ground surface Exception....
-
Resting Intervals [1016.8]
Resting intervals are required at the top and bottom of an ORAR section any time the running slope exceeds 1:20 (5 percent)....
-
§ 38.159(c)(5) Slope
(5) Slope. Ramps shall have the least slope practicable and shall not exceed 1:4 when deployed to ground level....
-
405.9.1 Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
-
11B-802.1.1 Floor or ground surface
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved....
- Figure 405.9.1 Extended Floor or Ground Surface Edge Protection – Drawing from the U.S. Access Board
-
Handrail Extensions: ADA Standard Section 505.10
Section 505.10 covers the current ADA Standards for handrail extensions.
-
206 and Chapter 4 Accessible Routes
[See subsections ...]
-
11B-502.4 Floor or ground surfaces
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved. Advisory 11B-502.4 Floor or ground surfaces....
-
405.9.1 Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
-
405.9.1 Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
-
405.9.1 Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
- Sears Brands, LLC Craftsman Digital Torpedo Level
-
505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....
-
505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....
-
505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....
-
505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....
-
Wheelchair Spaces
Wheelchair spaces must be level (2% maximum slope in any direction) and adjoining routes and maneuvering spaces must provide flush connections so that maneuvering to and from spaces does...
-
11B-1008.2.5.1 Ground level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....
-
1008.2.5.1 Ground Level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....
-
1008.2.5.1 Ground Level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....
-
11B-1008.2.5.1 Ground level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....
-
11B-1008.2.5.1 Ground level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....