Where elevated dune crossings or dune crossings steeper than 1:20 (5 percent) are part of beach access routes, handrails complying with ABAAS section 505 and edge protection complying...
Search Results "Raised Crossing"
-
6.12 Handrails and Edge Protection
-
1. & 2. Sidewalk Slope
1. ...do the sidewalks have cross slopes (i.e.: slopes tilting side to side) less than 1:50 (critical dimension of ´" or less) [sic] so persons who use wheelchairs can conveniently negotiate...
-
703.2.6 Stroke Thickness
703.2.6 Stroke Thickness. Stroke thickness of the uppercase letter "I" shall be 15 percent maximum of the height of the character.
-
11B-703.2.6 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character.
-
11B-407.4.6.2 Buttons
Car control buttons with floor designations shall comply with Section 11B-407.4.6.2. Exception: Reserved. [2010 ADAS] EXCEPTION: In existing elevators, buttons shall be...
-
703.2.6 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 15 percent maximum of the height of the character.
-
407.4.7.1.1 Type
Control buttons shall be identified by tactile characters complying with 703.2.
-
703.2.6 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 15 percent maximum of the height of the character. [ECTCR UFAS 4.30.4]
-
407.4.7.1.1 Type
Control buttons shall be identified by tactile characters complying with 703.2.
-
407.4.7.1.1 Type
407.4.7.1.1 Type. Control buttons shall be identified by tactile characters complying with 703.2.
-
11B-407.4.6.2 Buttons
Car control buttons with floor designations shall comply with Section 11B-407.4.6.2. Exception: Reserved. [2010 ADAS] EXCEPTION: In existing elevators, buttons shall be...
-
11B-703.2.6 Stroke thickness
11B-703.2.6 Stroke thickness. Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character.
-
11B-703.2.6 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character.
-
11B-407.4.6.2 Buttons
Car control buttons with floor designations shall comply with Section 11B-407.4.6.2. Exception: Reserved. [2010 ADA Standards] EXCEPTION: In existing elevators, buttons shall...
-
11B-407.4.7.2 Keypads
The number five key shall have a single raised dot. The dot shall be 0.118 inch (3 mm) to 0.120 inch (3.05 mm) base diameter and in other aspects comply with Table 11B-703.3.1....
-
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms....
-
11B-407.4.7.2 Keypads
The number five key shall have a single raised dot....
-
11B-407.4.7.2 Keypads
The number five key shall have a single raised dot....
-
4.7.10 Diagonal Curb Ramps
If diagonal curb ramps are provided at marked crossings, the 48 in (1220 mm) clear space shall be within the markings (see Fig. 15(c) and (d))....
-
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms Recommendations Description: Entry to wheelchair spaces on raised surfaces greater than ¼ inch in height requires a transition...
-
1.1.5
1.1.5 A maximum design cross slope for accessible exterior pedestrian paving and ramps of 1.5% (1:67 or about 3/16 in. per ft. [15 mm per m]) is recommended....
-
4.30.4* Raised and Brailled Characters and Pictorial Symbol Signs
4.30.4* Raised and Brailled Characters and Pictorial Symbol Signs (Pictograms)....
-
Changes in Level at Entry to Wheelchair Spaces (M303.3)
M303.3 includes technical criteria for changes in level at the entry to a wheelchair space as may occur at wheelchair weight scales with raised platforms....
-
4.7.10 DIAGONAL CURB RAMPS
If diagonal curb ramps are provided at marked crossings, the 48 in (1220 mm) clear space shall be within the markings (see Fig. 15(c) and (d))....