If a door has a closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (...
Search Results "Out-Swinging Door"
-
4.13.10* Door Closers
-
4.13.10* DOOR CLOSERS
If a door has a closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (...
-
Counter Surface Height
Specifications are provided for the counter surface height of check-out aisles, including the height of counter edge protection, which is limited to 2 inches above the counter surface (904.3.2...
-
Automatic Doors and Power Assisted Doors [4.13.12]
Automatic Doors and Power Assisted Doors [4.13.12] Automated doors are classified by industry standards according to the level of force produced by the door opening....
-
11B-404.2.9 Door and gate opening force
The force for pushing or pulling open a door or gate other than fire doors shall be as follows: 1. Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2. ...
-
11B-404.2.9 Door and gate opening force
The force for pushing or pulling open a door or gate other than fire doors shall be as follows: 1. Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2....
-
11B-404.2.9 Door and gate opening force
The force for pushing or pulling open a door or gate other than fire doors shall be as follows: Interior hinged doors and gates: 5 pounds (22.2 N) maximum....
-
Queues and Waiting Lines: ADA Standard Section 227.5
Section 227.5 covers scoping requirements in the current ADA Standards for queues and waiting lines.
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
7(2)(b)(i)
(i) Where the door swings into the bathroom, there is a clear space (approximately, 2' 6" by 4'0") within the room to position a wheelchair or other mobility aid clear of the path of the...
-
Shelves, Sales and Service Counters, and Check-Out Aisles
Shelves, Sales and Service Counters, and Check-Out Aisles The obligation to provide program access also applies to merchandise shelves, sales and service counters, and check-out aisles...
-
904.3.2 Counter
The top of the counter edge protection shall be 2 inches (51 mm) maximum above the top of the counter surface on the aisle side of the check-out counter....
-
11B-227.5 Queues and Waiting Lines
Queues and waiting lines servicing counters or check-out aisles required to comply with Sections 11B-904.3 or 11B-904.4 shall comply with Section 11B-403....
-
11B-227.5 Queues and Waiting Lines
Queues and waiting lines servicing counters or check-out aisles required to comply with Sections 11B-904.3 or 11B-904.4 shall comply with Section 11B-403....
-
11B-904.3.2 Counter
The top of the counter edge protection shall be 2 inches (51 mm) maximum above the top of the counter surface on the aisle side of the check-out counter....
-
904.3.2 Counter
The top of the counter edge protection shall be 2 inches (51 mm) maximum above the top of the counter surface on the aisle side of the check-out counter....
-
11B-404.2.9 Door and gate opening force
SECTION TITLE NOTES 11B-404.2.9 Door and gate opening force....
-
404.3.4 Doors in Series and Gates in Series
Doors in series and gates in series shall comply with 404.2.6....
-
404.3.4 Doors in Series and Gates in Series
Doors in series and gates in series shall comply with 404.2.6....
-
Door Maneuvering Clearance
It includes tables that specify these clearances according to the type of door, doorway, or gate (swinging, sliding, folding, and doorways without doors or gates) and the approach (front...
-
404.3.7 Revolving Doors, Revolving Gates, and Turnstiles
404.3.7 Revolving Doors, Revolving Gates, and Turnstiles. Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
Door Maneuvering Clearance
Table 404.2.4.1 specifies maneuvering clearances for manual swinging doors and gates....
-
Can elevator doors close sooner than the minimum opening time specified when users activate door close?
User activation of door close (or automatic operation) cannot reduce the initial opening time of doors (3 seconds minimum) or the minimum door signal timing (based on 1.5/ ft/s travel speed...
-
1008.4.1 Turning Space
Where swings are provided, the turning space shall be located immediately adjacent to the swing....