User activation of door close (or automatic operation) cannot reduce the initial opening time of doors (3 seconds minimum) or the minimum door signal timing (based on 1.5/ ft/s travel speed...
Search Results "Out-Swinging Door"
Commonly Searched Documents
-
Can elevator doors close sooner than the minimum opening time specified when users activate door close?
-
Must elevator doors remain open for 20 seconds?
LULA swing doors, private residence elevator doors, and platform lift gates and doors must remain open for 20 seconds minimum....
-
904 Check-Out Aisles and Sales and Service Counters
[See subsections ...]
-
904 Check-Out Aisles and Sales and Service Counters
[See subsections ...]
-
904.3.2 Counter
The top of the counter edge protection shall be 2 inches (51 mm) maximum above the top of the counter surface on the aisle side of the check-out counter....
-
11B-904.3.2 Counter
The top of the counter edge protection shall be 2 inches (51 mm) maximum above the top of the counter surface on the aisle side of the check-out counter....
-
11B-904.3.2 Counter
The top of the counter edge protection shall be 2 inches (51 mm) maximum above the top of the counter surface on the aisle side of the check-out counter....
-
A4.13.11(1) Hinged doors
(1) Hinged doors: Force applied perpendicular to the door at the door opener or 30 in (760 mm) from the hinged side, whichever is farther from the hinge....
-
A4.13.11(1) Hinged doors
(1) Hinged doors: Forced applied perpendicular to the door at the door opener or 30 in (760 mm) from the hinged side, whichever is farther from the hinge....
-
11B-404.2.7 Door and gate hardware
Exceptions: Existing locks shall be permitted in any location at existing glazed doors without stiles, existing overhead rolling doors or grilles, and similar existing doors or grilles...
-
407.3 Elevator Door Requirements
407.3 Elevator Door Requirements. Hoistway and car doors shall comply with 407.3....
-
404.2.2 Double-Leaf Doors and Gates
404.2.2 Double-Leaf Doors and Gates. At least one of the active leaves of doorways with two leaves shall comply with 404.2.3 and 404.2.4....
-
11B-809.10.4 Sufficient maneuvering space
Where doors swing into the toilet and bathing or powder rooms required to comply with Section 11B-809.10, a clear maneuvering space of 30 (762 mm) inches by 48 inches (1219 mm) minimum shall...
-
1008.4.1 Turning Space
Where swings are provided, the turning space shall be located immediately adjacent to the swing....
-
1008.4.1 Turning Space
Where swings are provided, the turning space shall be located immediately adjacent to the swing....
-
11B-404.3.4 Doors in series and gates in series
Doors in series and gates in series shall comply with Section 11B-404.2.6....
-
404.3.7 Revolving Doors, Revolving Gates, and Turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
404.3.7 Revolving Doors, Revolving Gates, and Turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
11B-404.3.4 Doors in series and gates in series
Doors in series and gates in series shall comply with Section 11B-404.2.6....
-
11B-404.3.4 Doors in series and gates in series
Doors in series and gates in series shall comply with Section 11B-404.2.6....
-
11B-1008.4.1 Turning space
Where swings are provided, the turning space shall be located immediately adjacent to the swing....
-
11B-1008.4.1 Turning space
Where swings are provided, the turning space shall be located immediately adjacent to the swing....
-
11B-1008.4.1 Turning space
Where swings are provided, the turning space shall be located immediately adjacent to the swing....