, measured perpendicular to the face of the door or gate...
Search Results "In-Swinging Door"
Commonly Searched Documents
-
11B-404.2.4.3 Recessed doors and gates
-
11B-404.2.4.3 Recessed doors and gates
, measured perpendicular to the face of the door or gate...
-
404.2 Manual Doors, Doorways, and Manual Gates
Manual doors and doorways and manual gates intended for user passage shall comply with 404.2....
-
404.2 Manual Doors, Doorways, and Manual Gates
Manual doors and doorways and manual gates intended for user passage shall comply with 404.2....
-
R218 Doors, Doorways, and Gates (Section-by-Section Analysis)
R218 Doors, Doorways, and Gates (Section-by-Section Analysis) Doors, doorways, and gates to pedestrian facilities such as transit shelters must comply with applicable technical requirements...
-
11B-411.3.4 Door delay
Door delay shall comply with Section 11B-407.3.5....
-
11B-411.3.4 Door delay
Door delay shall comply with Section 11B-407.3.5....
-
11B-411.3.4 Door delay
Door delay shall comply with Section 11B-407.3.5....
-
407.3.4 Door and Signal Timing
407.3.4 Door and Signal Timing....
-
4.13.6 MANEUVERING CLEARANCES AT DOORS
Minimum maneuvering clearances at doors that are not automatic or power-assisted shall be as shown in Fig. 25....
-
Power-Operated Doors or Gates
Platform lifts are required to have power-operated doors or gates....
-
Door Pressure Gauge
Door Pressure Gauge This Door Pressure Gauge, available from Evan Terry Associates, measures forces from 0-35 pounds on one side and 0-16 kilograms on the other....
-
4.13.6 Maneuvering Clearances at Doors
Minimum maneuvering clearances at doors that are not automatic or power-assisted shall be as shown in Fig. 25....
-
Usable Door
One commenter stated that a clear definition of "usable door" is required. Response....
-
404.2.10 Door and Gate Surfaces
404.2.10 Door and Gate Surfaces....
-
11B-404.2.2 Double-leaf doors and gates
At least one of the active leaves of doorways with two leaves shall comply with Sections 11B-404.2.3 and 11B-404.2.4.
-
11B-404.2.2 Double-leaf doors and gates
At least one of the active leaves of doorways with two leaves shall comply with Sections 11B-404.2.3 and 11B-404.2.4.
-
11B-404.2.2 Double-leaf doors and gates
At least one of the active leaves of doorways with two leaves shall comply with Sections 11B-404.2.3 and 11B-404.2.4.
-
§ 38.25(c) Door height
(c) Door height....
-
Opening Force [§404.2.9]
to fully open a door, not the initial force needed to overcome the door’s seal resulting from unequal pressure....
-
Power-Assisted Doors and Gates [§404.3]
Power-Assisted Doors and Gates [§404.3] Power-assisted devices reduce the opening force of doors with closing mechanisms....
-
404.2.10 Door and Gate Surfaces
Swinging door and gate surfaces within 10 inches (255 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
1132A.1 Primary entry doors and required exit doors
1132A.1 Primary entry doors and required exit doors. The width and height of primary entry doors and all required exit doors shall comply with Section 1126A.1....
-
404.2.10 Door and Gate Surfaces
Swinging door and gate surfaces within 10 inches (255 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...