Medical Care Facilities Requirements for alarms may be modified in medical care settings according to standard industry practice. In many health care facilities, personnel...
Search Results "Firing Position"
Commonly Searched Documents
-
Medical Care Facilities
-
5.9.1 Standing Supports Recommendation In Reference To Mammography Equipment
Instead, positioning supports should be required....
-
M305.5 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided....
-
M301.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided....
-
Public and Common Use Areas: ADA Standard Section 215.2
Section 215.2 covers scoping requirements in the current ADA Standards for fire alarm systems in public and common use areas.
-
11B-215.2 Public and common use areas
Alarms in public use areas and common use areas shall comply with Chapter 9, Section 907.5.2.3.1. [2010 ADA Standards] 215.2 Public and Common Use Areas. Alarms in public use...
-
M305.2.5 Surface Hazards (Section-by-Section Analysis)
Sharp edges or abrasive elements may injure and cause the patient to lose their grip during positioning or transfer.”...
-
5.3.2.2 Transfer Sides for Imaging Equipment
5.3.2.2 Transfer Sides for Imaging Equipment. The transfer surface should be provided on at least one long side of the table.
-
4.2.3 Operable Parts
Exception: Fire rings, grills, fireplaces, and wood stoves shall not be required to comply with ABAAS section 309.4 until models that comply are readily available from more than one source...
- Harris Communications SafeAwake on Welcome Home
- Harris Communications SafeAwake Instructional Video
-
M302.2.1 Adjustability
A low transfer position at a height of 17 inches (430 mm) minimum and 19 inches (485 mm) maximum; B. A high transfer position at 25 inches (635 mm); and C....
-
B. Summary of Major Provisions and Organization of Technical Criteria
The Access Board has divided the MDE Standards into separate technical criteria based on how the diagnostic equipment is used by the patient: (1) supine, prone, or side lying position (M301...
-
M302.2.1 Adjustability (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface height range for diagnostic equipment used by patients in a seated position of 17 inches minimum and 19 inches maximum....
-
M301.3.1 Transfer Supports (Section-by-Section Analysis)
The MDE NPRM proposed to require transfer supports to be provided for use with transfer sides on diagnostic equipment used by patients in the supine, prone, or side-lying position, and that...
-
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302
Sharp edges or abrasive elements may injure and cause the patient to lose his/her grip during positioning or transfer....
-
Signal Type: ADA Standard Section 407.4.8.2.1
Section 407.4.8.2.1 covers the current ADA Standards for the signal type of audible elevator car indicators.
-
11B-407.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop. Exception: For elevators that have a rated speed of 200 feet per...
-
11B-407.4.8.1.1 Size
Characters shall be ½ inch (12.7 mm) high minimum.
-
11B-411.4.8.1 Visible indicators
Visible indicators shall comply with Section 11B-411.4.8.1.
-
5.9.1 Standing Supports In Reference To Mammography Equipment
To be useful, positioning supports must be shaped for grasping, positioned within reach range of all users, and be 12 inches long minimum when located on the moving C-arm or 18 inches long...
-
5.1 Transfer Surface Height
5.1 Transfer Surface Height
-
5.1.4 Transfer Surface Height Measurement
5.1.4 Transfer Surface Height Measurement. The transfer surface height should be measured from the floor to the highest point on the seat in an uncompressed state, inclusive of...
-
M305.3.1.1 Horizontal Position
The length of gripping surfaces on horizontal standing supports shall be 4 inches (100 mm) minimum except for diagnostic equipment containing a wheelchair space which shall comply...