Exception: Where bedrock, perma-frost or other environmental conditions prohibit a level entry or the toilet design (such as a composting toilet) necessitates a raised toilet structure,...
Search Results "Entry Door (FHA)"
Commonly Searched Documents
- 
    
  
  5.3.6 Entrance
  
- 
    
  
  R218 Doors, Doorways, and Gates (Section-by-Section Analysis)
  R218 Doors, Doorways, and Gates (Section-by-Section Analysis) Doors, doorways, and gates to pedestrian facilities such as transit shelters must comply with applicable technical requirements... 
- 
    
  
  11B-411.3.4 Door delay
  Door delay shall comply with Section 11B-407.3.5.... 
- 
    
  
  11B-411.3.4 Door delay
  Door delay shall comply with Section 11B-407.3.5.... 
- 
    
  
  11B-411.3.4 Door delay
  Door delay shall comply with Section 11B-407.3.5.... 
- 
    
  
  Must elevator doors remain open for 20 seconds?
  LULA swing doors, private residence elevator doors, and platform lift gates and doors must remain open for 20 seconds minimum.... 
- 
    
  
  Door Pressure Gauge
  Door Pressure Gauge This Door Pressure Gauge, available from Evan Terry Associates, measures forces from 0-35 pounds on one side and 0-16 kilograms on the other.... 
- 
    
  
  11B-604.8.1.1.2 Maneuvering space with side-opening door
  In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep... 
- 
    
  
  11B-224.1.2 Guest room doors and doorways
  11B-404.2.3 _|Doors, Doorways, and Gates; Clear Width|_.... 
- 
    
  
  11B-224.1.2 Guest room doors and doorways
  11B-404.2.3 _|Doors, Doorways, and Gates; Clear Width|_.... 
- 
    
  
  11B-224.1.2 Guest room doors and doorways
  Bathrooms doors shall be either sliding or hung to swing in the direction of egress from the bathroom. [2010 ADA Standards] 224.1.2 Guest Room Doors and Doorways.... 
- 
    
  
  Medical Diagnostic Equipment Accessibility Standards Sub-Committee Recommendations Weight Scales
  Criteria Applies Seated in a wheelchair (M303) Wheelchair space, including orientation, width, depth, knee and toe clearance, and surface slope Changes in level at entry... 
- 
    
  
  11B-404.2.2 Double-leaf doors and gates
  At least one of the active leaves of doorways with two leaves shall comply with Sections 11B-404.2.3 and 11B-404.2.4. 
- 
    
  
  11B-404.2.2 Double-leaf doors and gates
  At least one of the active leaves of doorways with two leaves shall comply with Sections 11B-404.2.3 and 11B-404.2.4. 
- 
    
  
  11B-404.2.2 Double-leaf doors and gates
  At least one of the active leaves of doorways with two leaves shall comply with Sections 11B-404.2.3 and 11B-404.2.4. 
- 
    
  
  Break Out Opening: ADA Standard Section 404.3.6
  Section 404.3.6 covers the current ADA Standards for the break out openings at swinging or sliding doors and gates. 
- 
    
  
  Handrails
  Handrails Sloped entries must have handrails on both sides regardless of the slope. Handrail extensions are required at the top landing but not at the bottom.... 
- 
    
  
  7(2)(b)(iii)
  (iii) When both tub and shower fixtures are provided in the bathroom, at least one is made accessible. When two or more lavatories in a bathroom are provided, at least one is made... 
- 
    
  
  Section 3. Fair Housing Act Design and Construction Requirements
  This section reprints §100.205 (Design and Construction Requirements) from the Department's final rule implementing the Fair Housing Act. A reprint of §100.205 was included to... 
- 
    
  
  21.1 Q. Is a dwelling unit that has a split entry foyer...required to be accessible if it is a ground floor unit in a covered multifamily dwelling?
  A. Yes. Under Requirement 4, there must be an accessible route into and through the dwelling unit. This would preclude a split level foyer, unless a properly sloped ramp can be... 
- 
    
  
  § 38.25(c) Door height
  (c) Door height.... 
- 
    
  
  11B-404.3.6 Break out opening
  Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated... 
- 
    
  
  Door Maneuvering Clearance
  Section 404.2.4 addresses maneuvering clearances at manual doors, doorways, and gates.... 