(2) Clear aisle width for accessible check-out aisles shall comply with 4.2.1 and maximum adjoining counter height shall not exceed 38 in (965 mm) above the finish floor....
Search Results "Door Clear Width"
Commonly Searched Documents
-
7.3(2)
-
405.5 Clear Width
The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum....
-
405.5 Clear Width
The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum....
-
Accessible Route
accessible route but where they are required to comply with 4.9, it is recommended that routes to them meet the requirements for accessible routes since certain specifications, such as clear...
-
Clear Deck Space: ADA Standard Section 1009.4.1
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-404.2.4.3 Recessed doors and gates
, measured perpendicular to the face of the door or gate...
-
Manual Doors, Doorways, and Manual Gates: ADA Standard Section 404.2
Section 404.2 covers the current ADA Standards for manual doors, doorways and manual gates that are part of an accessible route.
-
11B-411.3.4 Door delay
Door delay shall comply with Section 11B-407.3.5....
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
Handrails
The clear width between handrails must be between 33 and 38 inches. The handrail height must be between 34 and 38 inches to the top of the gripping surface....
-
11B-404.2.2 Double-leaf doors and gates
At least one of the active leaves of doorways with two leaves shall comply with Sections 11B-404.2.3 and 11B-404.2.4.
-
8.5 Stacks
Minimum clear aisle width between stacks shall comply with 4.3, with a minimum clear aisle width of 42 in (1065 mm) preferred where possible....
-
8.5 STACKS
Minimum clear aisle width between stacks shall comply with 4.3, with a minimum clear aisle width of 42 in (1065 mm) preferred where possible....
-
11B-404.2 Manual doors, doorways, and manual gates
Manual doors and doorways and manual gates intended for user passage shall comply with Section 11B-404.2....
-
11B-1009.2.5 Seat width
The seat shall be 16 inches (406 mm) wide minimum.
-
11B-404.3 Automatic and power-assisted doors and gates
Automatic doors and automatic gates shall comply with Section 11B-404.3. Full-powered automatic doors shall comply with ANSI/BHMA A156.10....
-
Controls [§404.3.5]
Controls [§404.3.5] Door and gate controls must be compliant as operable parts (operable with one hand and without tight grasping, pinching, twisting of the wrist, or more than 5 lbf)...
-
904.3.1 Aisle
Aisles shall comply with 403.
-
SECTION 1017 AISLES
SECTION 1017 AISLES [DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where...
-
11B-904.3.1 Aisle
Aisles shall comply with Section 11B-403.
-
904.3.1 Aisle
Aisles shall comply with 403.
-
E1-a
E1-a. Is there an accessible route, at least 36 inches wide, that connects the accessible entrance to all shelter areas (it may narrow to 32 inches wide for up to 2 feet in length)?...
-
904.3.1 Aisle
904.3.1 Aisle. Aisles shall comply with 403.
-
E1-1. Accessible Route
E1-1. Is there an accessible route, at least 36 inches wide that connects the accessible entrance to the voting area (the accessible route may narrow to 32 inches wide for up to 2...