Clear floor or ground space complying with 305.2 and 305.3 shall be provided at play components. Advisory 1008.4.2 Clear Floor or Ground Space....
Search Results "Door Clear Width"
Commonly Searched Documents
-
Clear Floor or Ground Space: ADA Standard Section 1008.4.2
-
2. b. WIDE AND EASY TO OPEN EXTERIOR AND INTERIOR DOORS
[See subsections ...]
-
Clear Floor or Ground Space: ADA Standard Section 804.6.1
A clear floor or ground space complying with 305 shall be provided at each kitchen appliance. Clear floor or ground spaces shall be permitted to overlap....
- Figure 1009.3.3 Handrails for Sloped Entry – Drawing from the U.S. Access Board
-
1132A.3 Width and height of interior doors and secondary exterior doors
Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
-
11B-206.5 Doors, doorways, and gates
Doors, doorways, and gates providing user passage shall be provided in accordance with Section 11B-206.5....
-
1018.3 Aisles in Groups B and M
In Group B and M occupancies, the minimum clear aisle width shall be determined by Section 1005.1 for the occupant load served, but shall be not less than that required for corridors by...
-
11B-703.8.6 Stroke width
The uppercase letter “I” shall be used to determine the allowable stroke width of all low resolution VMS characters of a font....
- Figure 604.8.1.2 Wheelchair Accessible Toilet Compartment Doors – Drawing from the U.S. Access Board
-
803.3 Door Swing
803.3 Door Swing. Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
1017.3 Aisles in Groups B and M
In Group B and M occupancies, the minimum clear aisle width shall be determined by Section 1005.1 for the occupant load served, but shall not be less than 36 inches (914 mm)....
-
1018.3 Aisles in Groups B and M
In Group B and M occupancies, the minimum clear aisle width shall be determined by Section 1005.1 for the occupant load served, but shall not be less than that required for corridors by...
-
405.5 Clear Width
405.5 Clear Width. The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum....
-
1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (840 mm) minimum and 38 inches (965 mm) maximum. EXCEPTIONS: 1....
-
1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (840 mm) minimum and 38 inches (965 mm) maximum. EXCEPTIONS: 1....
-
Door Swing [§304.4] and Other Space Requirements
Door Swing [§304.4] and Other Space Requirements Doors can swing into the turning space....
-
1018.5 Aisles in other than assembly spaces and Groups B and M
In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load served...
-
1018.5 Aisles in other than assembly spaces and Groups B and M
In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load served...
-
1017.3 Clear Tread Width
This section requires the clear tread width of trails to be 36 inches minimum....
-
Guest Rooms
Because of the social interaction that often occurs in lodging facilities, an accessible clear opening width is required for doors and doorways to and within all guest rooms, including those...
-
803.3 Door Swing
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
803.3 Door Swing
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
Double-Leaf Doors and Gates: ADA Standard Section 404.2.2
Section 404.2.2 covers the current ADA Standards for double-leaf doors and gates that are part of an accessible route.
-
10.3.1(16)
(16) Where provided in below grade stations, escalators shall have a minimum clear width of 32 inches....