The clear space and additional maneuvering space shall be 915 mm (3.0 ft) wide minimum where the depth exceeds 610 mm (2.0 ft)....
Search Results "Clear Deck Space"
Commonly Searched Documents
-
R404.7.1 Forward Approach
-
R404.7.2 Parallel Approach
The clear space and additional maneuvering space shall be 1525 mm (5.0 ft) wide minimum where the depth exceeds 380 mm (1.25 ft)....
-
1006.4 Weather Shelters
A clear floor or ground space 60 inches (1525 mm) minimum by 96 inches (2440 mm) minimum shall be provided within weather shelters....
-
Forward and Side Approaches
At most elements, clear floor space can be positioned for either a forward approach or a side approach....
-
Water Closet Clear Floor Space in Toilet Compartments
The Board has not revised the minimum dimensions for the clear floor space at water closets....
-
11B-603.2.3 Door swing
Doors shall not swing into the clear floor space or clearance required for any fixture....
-
11B-603.2.3 Door swing
Doors shall not swing into the clear floor space or clearance required for any fixture....
-
11B-305.7 Maneuvering clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with Sections...
-
305.7 Maneuvering Clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1...
-
11B-305.7 Maneuvering clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with Sections...
-
11B-305.7 Maneuvering clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with Sections...
- Magnuson Group BALLOON Outdoor Waste Receptacle
- Landscape Forms Inc. Petoskey Trash Receptacle
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Scooter
This data depicts the amount of clear floor area required by persons using wheeled mobility devices when performing a forward or side reach to a target location (e.g., reaching to a...
-
4.33.2* Size of Wheelchair Locations
Each wheelchair location shall provide minimum clear ground or floor spaces as shown in Fig. 46....
-
4.33.2* SIZE OF WHEELCHAIR LOCATIONS
Each wheelchair location shall provide minimum clear ground or floor spaces as shown in Fig. 46....
- 305.3 Package Drop Box Clear Floor Space
-
3.3.3 Clear Floor Width
3.3.3 Clear Floor Width The findings on clear floor width are based on the findings on occupied width from anthropometric studies shown in Figure 3‒3....
- Landscape Forms Inc. Chase Park Trash Receptacle
-
11B-809.9.1 Clear floor space
Clear floor spaces 30 inches (762 mm) by 48 inches (1219 mm), with centerlines aligned with the centerline of the work surface, appliance, sink or fixture, shall be provided in the following...
-
Clear Ground Space [1013.2]
A clear ground space at least 48 inches wide must be provided on all usable sides of tent pads and tent platforms....
-
3.3.4 Clear Floor Length
3.3.4 Clear Floor Length The mean value of clear floor length for our study (1250 mm or 49 in.) is above the clear floor length provided in the U.S. standards (1220 mm or 48 in.)....
-
3.4.7 Openings
Openings in the clear ground space and turning space surface shall not allow passage of a sphere more than 1/2 inch (13 mm) diameter....
-
5.3.2.3 Slope
The slope of the turning space and clear floor or ground space surface shall not be steeper than 1:48 (2 percent) in all directions....