207.1 General
-
1010.1.7 Thresholds
The door is not part of the required means of egress. 1.2. The door is not part of an accessible route as required by Chapter 11A or 11B. 1.3....
-
1007.6.5 Identification
Each door providing access to an area of refuge from an adjacent floor area shall be identified by a sign complying with ICC A117.1, stating: AREA OF REFUGE, and including the International...
-
1003.2.13.5.5 Identification
Each door providing access to an area of refuge from an adjacent floor area shall be identified by a sign complying with ICC A117.1, stating: AREA OF REFUGE, and including the International...
-
1009.2 Continuity and components
Each required accessible means of egress shall be continuous to a public way and shall consist of one or more of the following components:...
-
1007.8.2 Exterior exit stairway
Exterior exit stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1219 mm) between handrails....
-
1007.2 Continuity and components
Each required accessible means of egress shall be continuous to a public way and shall consist of one or more of the following components:...
-
Accessible Routes: ADA Standard Section 402
Section 402 covers the current ADA Standards for accessible routes.
-
1007.4 Elevators
An elevator to be considered part of an accessible means of egress shall comply with the emergency operation and signaling device requirements of Section 2.27 of ASME A17.1....
-
1007.6 Areas of refuge
Every required area of refuge shall be accessible from the space it serves by an accessible means of egress....
-
703.7.2.1 International Symbol of Accessibility
(F216.5) If the main entrance to a building is not accessible, the ISA and an arrow to be posted to direct to closest accessible entrance....
-
Relationship to Accessible Routes: ADA Standard Section 502.7
Section 502.7 covers the current ADA Standards for the relationship between accessible parking spaces and accessible routes.
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated...
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated...
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated...
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
A4.3.11.3 Stairway Width
A 48 in (1220 mm) wide exit stairway is needed to allow assisted evacuation (e.g., carrying a person in a wheelchair) without encroaching on the exit path for ambulatory persons.
-
Accessible Routes: ADA Standard Section 206
Section 206 covers scoping requirements for accessible routes in the most current ADA Standards.
-
11B-216.4.4 Delayed egress locks
Signs required by Chapter 10, Section 1010.1.9.7, Item 6.4 at doors with delayed egress locks shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5....
-
11B-216.4.4 Delayed egress locks
Signs required by Chapter 10, Section 1010.1.9.7, Item 6.4 at doors with delayed egress locks shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5....
-
404.3.2 Maneuvering Clearance
Clearances at automatic doors and gates without standby power and serving an accessible means of egress shall comply with 404.2.4....
-
404.3.2 Maneuvering Clearance
Clearances at automatic doors and gates without standby power and serving an accessible means of egress shall comply with 404.2.4....