Where the passing space is the intersection of two trails, the intersection must be as flat as possible so that all of the wheels of a mobility device touch the ground when turning into...
Search Results "Ground Level Play Component"
-
1017.4.1 Size
-
Problem Four (Accessible Route)
Or, if a church basement located down a flight of stairs is used as the voting area, perhaps one of the ground floor rooms could be used as the voting area....
-
11B-904.4 Sales and service counters
existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with Section 11B-904.4.1 provided that the required clear floor or ground...
-
Protruding Objects [1016.9]
To prevent injuries to people who are blind or have low vision, whenever possible, maintain the vertical clearance free of tree branches a minimum of 80 inches above the ground surface along...
-
606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (865 mm) maximum above the finish floor or ground. EXCEPTIONS: 1....
-
Protruding Objects [4.4]
The diagonal technique involves holding the cane in a stationary position diagonally across the body with the bottom tip at the ground beyond one shoulder and the grip extending beyond the...
-
Scoping [4.1.3(8)]
of the number of public entrances (whichever is greater); and at least one entrance to each separate tenancy is accessible at least one accessible entrance serves the ground...
-
1017.4.1 Size
Where the passing space is the intersection of two trails, the intersection must be as flat as possible so that all of the wheels of a mobility device touch the ground when turning into...
- Bradley Advocate AV-Series AV30 Lavatory, Soap & Hand Dryer
-
Tom Williams, AIA, National Accessibility Officer, GSA, Public Buildings Service
Some of the most recent coatings are very, very effective at reducing solar energy in interior spaces as well as controlling the level of light that you get....
-
Documentation of Impact and Validity Evidence
Descriptions of educational levels, length of service, and age are also desirable. (7) Description of selection procedures. ...
-
§1607.15 Documentation of impact and validity evidence.
Descriptions of educational levels, length of service, and age are also desirable. (7) Description of selection procedures. ...
-
1009.8 Two-way communication
with Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is one or more stories above or below the level...
-
1009.8 Two-way communication
with Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is one or more stories above or below the level...
-
Service Counters
The accessibility requirements for service counters allow for some level of creative design. ...
-
4 [§ 4.7.2]
To measure the gutter slope, place the level in the same position as the arrow in the illustration, with one end where the gutter meets the ramp and the other end towards the street....
-
§382.41(c)
(c) Any aircraft-related, service-related or other limitations on the ability to accommodate passengers with a disability, including limitations on the availability of level-entry boarding...
-
11B-216.5.2 Parking facilities
Signs intended for use by pedestrians within parking facilities, including directional or informational signs indicating parking sections or levels, shall comply with the requirements of...
-
907.2.4 Group F
A manual fire alarm system shall be installed in Group F occupancies that are two or more stories in height and have an occupant load of 500 or more above or below the lowest level of exit...
-
A. Slope at Door
If a fully automatic door is not provided, is the walkway in front of the lobby door level, without any portion steeper than 1:50 (critical dimension of ´" or less), so persons who use wheelchairs...
-
12143(c)(5) Additional services
circumstances under which the Secretary may require a public entity to provide, notwithstanding paragraph (4), paratransit and other special transportation services under this section beyond the level...
-
Designed Use
It is an FTDS term for the intended use that controls the geometric design of a trail and determines the level to which it should be maintained....
-
2.6.1.2
Vertical alignment at the intersection of the outdoor recreation access routes that form the T-shaped space shall be nominally level....
-
Security Barriers [§206.8]
routes can be adjacent to metal detectors and other screening devices that do not accommodate all people with disabilities, but the route must be located so users can maintain an equivalent level...