Section 221.2.1.2 covers scoping requirements in the ADA for wheelchair spaces at luxury boxes, club boxes, and suites in arenas, stadiums and grandstands.
Search Results "Water Closet Clear Floor Space"
-
Luxury Boxes, Club Boxes, and Suites in Arenas, Stadiums, and Grandstands: ADA Standard Section 221.2.1.2
-
Catch Pools
Catch Pools A catch pool is a body of water where water slide flumes drop users into the water. An accessible means of entry or exit is not required into the catch pool....
-
Appendix Three: Bibliography
Space Requirements for Wheeled Mobility Devices in Public Transportation: Analysis of Clear Floor Space Requirements....
-
302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than 1/2 inch (13 mm) diameter except as allowed in 407.4.3, 409.4.3, 410.4, 810.5.3 and 810.10....
-
1132A.3, Item 2
Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
-
2.3.3 Comparison of Dimensions with Standards and other Anthropometric Studies
• Clear Floor Space Width: Compared to Occupied Width. • Clear Floor Space Length: Compared to Occupied Length....
-
11B-220.2 Point-of-sale devices
Where point-of-sale devices are provided at check stands and sales and service counters, they shall comply with Section 11B-707.9.1, and shall also comply with Sections 11B-707.2 _|Clear...
-
2.6.1.1
A space 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum; or...
-
11B-250.1 General
Vehicular traffic includes travel through parking facilities, into and out of parking spaces, into and out of electric vehicle charging spaces, and along roadways, driveways and drive aisles...
-
11B-221.2.1.2 Luxury boxes, club boxes, and suites in arenas, stadiums, and grandstands
In each luxury box, club box, and suite within arenas, stadiums, and grandstands, wheelchair spaces complying with Section 11B-802.1 shall be provided in accordance with Table 11B-221.2.1.1...
-
M303.2.5 Surfaces (Section-by-Section Analysis)
The MDE NPRM proposed to require diagnostic equipment used by patients seated in a wheelchair to provide a wheelchair space with a surface that does not slope more than 1:48 in any direction...
- Magnuson Group DS Series Wall Coat Racks
-
1132A.3, Item 5
A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle of 90 degrees...
-
9.2* POST OFFICE LOBBIES
Clear passageways in front of customer service counters shall be not less than 48 in (1220 mm) clear width to permit maneuvering of a wheelchair....
-
11B-812.6.3 Ambulatory
Vehicle spaces serving ambulatory EVCS shall be 120 inches (3048 mm) wide minimum and shall not be required to have an adjacent access aisle....
-
General: ADA Standard Section 226.1
Section 226.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for dining surfaces and work surfaces.
-
II-6.4000 Leased buildings
Public entities are encouraged, but not required, to lease accessible space....
-
Picnic Units
The minimum size of a picnic unit is determined by the required clear space around each feature and the type and number of provided constructed features Ensure all pedestrian routes that...
-
Protruding Objects
One element of a barrier-free meeting space for participants who are blind or have low vision requires cane-detectable protruding objects and sufficient head clearance....
-
What Other Accessibility Requirements Apply to Play Components?
The play area guidelines address accessible routes connecting play components along with certain spaces that are crucial to making a play area usable for children with disabilities....
-
Accessible route
• Clear, wide paths without stairs to the establishment’s entrance and throughout the business leave room for canes and walkers and accommodate people with reduced mobility and stamina....
-
d. i.
or pull open at the following locations: (1) Spy City Café men's and women's toilet rooms; (2) Main Lobby restrooms vestibule; (3) Main Lobby women's toilet room; (4) Second floor...
-
i. Medical examination and treatment tables and chairs
in the course of its enforcement efforts that medical and dental examination tables and chairs often are too high to be accessible, lack stabilization elements, and do not have adequate clear...
- Sioux Chief DropKick™ Offset Flange 889-45PAM