Support arm, 852 mm, ergonomically shaped to provide a clear sense of where the support arm ends. For fixed mounting. Foldable....
Search Results "Clear Deck Space"
Commonly Searched Documents
- Pressalit Care PLUS Support Arm Fixed Height Swing Grab Bar
-
When Ramps Are Required
For example, to reach a 12-inch high deck or platform, a designer could use a 12-foot ramp with the maximum 1:12 slope, or a 14-foot ramp with a less-steep 1:14 slope....
-
LULA Elevator Dimensions
The guidelines specify that LULA elevator cars be at least 42 inches wide and 54 inches deep with a door on the narrow end providing at least 32 inches clear width (408.4.1)....
-
Automatic Door Break Out Openings
The 2010 Standards at sections 404.1, 404.3, 404.3.1, and 404.3.6 require automatic doors that are part of a means of egress and that do not have standby power to have a 32-inch minimum clear...
-
1132A.3 Width and height of interior doors and secondary exterior doors
Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
-
R210 Protruding Objects
Objects along or overhanging any portion of a pedestrian circulation path shall comply with R402 and shall not reduce the clear width required for pedestrian access routes....
-
Vertical Clearance: ADA Standard Section 502.5
Section 502.5 covers the current ADA Standards for the vertical clearance required at accessible parking spaces.
- Tenon LLC
- LaCantina Multi-slide Contemporary Clad Sliding Door System
-
4.8.4(2)
(2) The landing length shall be a minimum of 60 in (1525 mm) clear....
- Garaventa Artira Inclined Platform Wheelchair Lift
- American Specialties Recessed Paper Towel Dispenser 6457
- Activar JL Industries Cosmopolitan Series 2035S21 Stainless Steel Fire Extinguisher Cabinet
-
809 Residential Dwelling Units
809 Residential Dwelling Units 809 Residential Dwelling Units 809.1 General 809.1 General 809.2 Accessible Routes 809.2.1 Location 809.2.2 Turning Space...
-
Alterations: ADA Standard Section 202.3
Section 202.3 covers the most current requirements for alterations in existing building and facilities.
- Gamco Automatic Wall Mounted Liquid Soap Dispenser - G-950SA
-
405.7.3 Length
The landing clear length shall be 60 inches (1525 mm) long minimum....
-
405.7.3 Length
The landing clear length shall be 60 inches (1525 mm) long minimum....
-
11B-405.7.3 Length
The landing clear length shall be 60 inches (1524 mm) long minimum....
-
11B-405.7.3 Length
The landing clear length shall be 60 inches (1524 mm) long minimum....
-
11B-405.7.3 Length
The landing clear length shall be 60 inches (1524 mm) long minimum....
-
EXTREME WEATHER
Cooling centers are air conditioned spaces such as senior centers, community centers, public libraries, and other public facilities that typically operate during daytime hours and are free...
-
11B-1009.2.6 Footrests and armrests
The armrest positioned opposite the water shall be removable or shall fold clear of the seat when the seat is in the raised position. [2010 ADAS] 1009.2.6 Footrests and Armrests. ...