Where possible, elongated openings should be placed perpendicular, or as close to perpendicular as possible, to the dominant direction of travel or outside of the clear width of the beach...
Search Results "Door Clear Width"
-
Openings [1018.6]
-
Escalators
Escalators must have a clear width of at least 32” and meet specific provisions in the ASME A17.1 Safety Code for Elevators and Escalators....
-
Character Spacing: ADA Standard Section 703.2.7
Where characters have rectangular cross sections, spacing between individual raised characters shall be 1/8 inch (3.2 mm) minimum and 4 times the raised character stroke width maximum....
-
11B-703.2.7 Character spacing
Where characters have rectangular cross sections, spacing between individual raised characters shall be 1/8 inch (3.2 mm) minimum and 4 times the raised character stroke width maximum....
-
11B-703.2.7 Character spacing
Where characters have rectangular cross sections, spacing between individual raised characters shall be 1/8 inch (3.2 mm) minimum and 4 times the raised character stroke width maximum....
-
1. Snow and Ice
Except in extreme conditions that rise to the level of a direct threat to the driver or others, a passenger's request for a paratransit driver to walk over a pathway that has not been fully cleared...
-
1. Snow and Ice
Except in extreme conditions that rise to the level of a direct threat to the driver or others, a passenger's request for a paratransit driver to walk over a pathway that has not been fully cleared...
-
Symbols: ADA Standard Section 407.4.7.1.3
Section 407.4.7.1.3 covers the current ADA Standards for the designation and indicator symbols on elevator car control buttons.
-
Kitchen Appliances
Section 309 includes specifications for clear floor space (309.2), height (309.3), and operating characteristics (309.4)....
- Inpro Corporation ENDURANT® Floor-to-Ceiling Mounted Partitions
-
Plantronics Clarity Ensemble TTY Phone
Requires the Registered User plan or above. Login!
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
Floor and Ground Surfaces
interior and exterior accessible routes, including walking surfaces, ramps, elevators, and lifts stairways that are part of a means of egress required clearances, including clear...
-
Openings [1016.6]
Where possible, drainage grates should be located outside the minimum clear width of the ORAR....
-
Maintaining Accessibility in Museum Shops
Museum shops must not allow merchandise to spill into aisles and narrow the width of the accessible route....
-
9.5 LOCKER ROOMS
Unobstructed aisle space in front of lockers used by handicapped people shall be a minimum of 42 in (1065 mm) clear width....
-
Protruding Objects and Outdoor Recreation Access Routes
Protruding objects are defined as constructed features (such as signs) that extend into the clear width area of an outdoor recreation access route, resting interval, or passing space and...
-
1016.4 Passing Spaces
This section requires passing spaces to be provided at intervals of 200 feet maximum where the clear width of outdoor recreation access routes is less than 60 inches....
-
Vision Lights: ADA Standard Section 404.2.11
Section 404.2.11 covers the current ADA Standards for vision lights on manual doors and gates.
-
11B-809.10.5.4 Bathtub enclosures
Doors and panels of bathtub enclosures shall be constructed from approved, shatter-resistant materials. Hinged doors shall open outward....
-
11B-809.10.5.4 Bathtub enclosures
Doors and panels of bathtub enclosures shall be constructed from approved, shatter-resistant materials. Hinged doors shall open outward....
-
809.2.2 Turning Space
EXCEPTION: Turning space shall not be required in exterior spaces 30 inches (760 mm) maximum in depth or width. Advisory 809.2.2 Turning Space....
-
809.2.2 Turning Space