4.34.6.8* REFRIGERATOR/FREEZER
refrigerator/freezer type; or (2) Of the over-and-under type and meet the following requirements: (a) Have at least 50 percent of the freezer space below 54 in (1370 mm) above the floor...
-
M302.4.1 Clearance in Base
The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured...
-
M301.4.1 Clearance in Base
The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured...
-
11B-411.2.1.7.3 Assignment by security credential
Upon presentation of security credential, the destination floor shall be confirmed by verbal announcement and on the display screen....
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
11B-217.4.1 Bank requirement
[2010 ADAS] EXCEPTION: TTYs shall not be required at banks of telephones located within 200 feet (61 m) of, and on the same floor as, a bank containing a public TTY....
-
11B-610.2 Bathtub seats
The top of bathtub seats shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
-
11B-411.2.1.7.3 Assignment by security credential
Upon presentation of security credential, the destination floor shall be confirmed by verbal announcement and on the display screen....
-
11B-804.3 Kitchen work surface
In kitchens within multi-bedroom housing units and on floors containing accessible sleeping rooms with adaptable features in undergraduate student housing, at least one 30 inches (762 mm...
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
11B-604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (356 mm) minimum and 19 inches (483 mm) maximum above the finish floor....
-
Maintenance
One site utilizing PIP as the primary access route and EWF as the secondary access route was assessed with less than 1 percent slope at the transition between the two surface materials. ...
-
Develop a Transition Plan
Where a public entity has responsibility or authority over streets, roads, or walkways, its transition plan must include a schedule for providing curb ramps or other sloped areas where pedestrian...
-
A) Accessible Parking
Access aisle of at least 60-inch width must be level (1:50 maximum slope in all directions), be the same length as the adjacent parking space(s) it serves and must connect to an accessible...
-
4. Overhead PV Systems
The project, including incidental work to implement a) and b) above, is not an alteration that would trigger path of travel upgrades;11 When located on sloping ground (running slope...
-
Bonded Impact/cushioning Surfaces
A1 and E1 were on a slope to assure drainage of the entire test surface. All surfaces used Engineered Wood Fiber (EWF), as defined by ASTM F2075-01....
-
11B-206.2.1 Site arrival points
(1) Newly constructed or altered streets, roads, and highways must contain curb ramps or other sloped areas at any intersection having curbs or other barriers to entry from a street...
- Wikk Industries Inc. Bollard With Push Plate PART# BPS SM PRP36 CL (628)
- Wikk Industries Inc. Bollard With Push Plate PART# BPS SM TUBE 32D (630)
- Murdock Manufacturing Grab Bars
-
Section D: Entrances
(§404.2.4) D4 Is the area in front of the door level, with slopes no greater than 1:48 in all directions?...
-
2. Shared Use Paths
, which address access to sidewalks, streets, and other pedestrian facilities, provide requirements for pedestrian access routes, including specifications for route width, grade, cross slope...
-
2. Shared Use Paths
, which address access to sidewalks, streets, and other pedestrian facilities, provide requirements for pedestrian access routes, including specifications for route width, grade, cross slope...