Standard toilet stalls with a minimum depth of 56 in (1420 mm) (see Fig. 30(a)) shall have wall-mounted water closets....
Search Results "Minimum Dimension"
-
4.17.3* Size and Arrangement
-
Attachment G
Examine all data tables to ensure that, at a minimum, row and column header cells are marked up correctly....
-
4.6.3* PARKING SPACES
Parking spaces for disabled people shall be at least 96 in (2440 mm) wide and shall have an adjacent access aisle 60 in (1525 mm) wide minimum (see Fig. 9)....
-
11B-411.2.2.2 Verbal identification
The verbal annunciator shall have a frequency of 300 Hz minimum and 3000 Hz maximum....
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (12.7 mm) maximum within 10 inches (254 mm) horizontally of the minimum landing area...
-
11B-1003.2.2 Boarding piers at boat launch ramps
Where the total length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9144 mm) minimum, gangways shall not be required to comply with Section...
-
11B-1002.4.4.2 Side entry
For example, where a 42 inch (1065 mm) opening is provided, a minimum clear space of 60 inches (1525 mm) in length and 36 inches (915mm) in depth is needed to ensure adequate space for maneuvering...
-
11B-221.2.1.1 General seating
TABLE 11B-221.2.1.1 NUMBER OF WHEELCHAIR SPACES IN ASSEMBLY AREAS Number Of Seats Minimum Number Of Required Wheelchair Spaces 4 to 25 1...
-
11B-607.6 Shower spray unit and water
A shower spray unit with a hose 59 inches (1499 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
11B-411.2.2.2 Verbal identification
The verbal annunciator shall have a frequency of 300 Hz minimum and 3000 Hz maximum....
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (12.7 mm) maximum within 10 inches (254 mm) horizontally of the minimum landing area...
-
11B-1002.4.4.2 Side entry
For example, where a 42 inch (1065 mm) opening is provided, a minimum clear space of 60 inches (1525 mm) in length and 36 inches (915mm) in depth is needed to ensure adequate space for maneuvering...
-
11B-1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (838 mm) minimum and 38 inches (965 mm) maximum....
-
11B-221.2.1.1 General seating
TABLE 11B-221.2.1.1 NUMBER OF WHEELCHAIR SPACES IN ASSEMBLY AREAS NUMBER OF SEATS MINIMUM NUMBER OF REQUIRED WHEELCHAIR SPACES...
-
702.1 General
except that the maximum allowable sound level of audible notification appliances complying with section 4-3.2.1 of NFPA 72 (1999 edition) shall have a sound level no more than 110 dB at the minimum...
-
404.2.9 Door and Gate Opening Force
Fire doors shall have a minimum opening force allowable by the appropriate administrative authority....
-
233.3.4 Alterations
accessible route to a residential dwelling unit, the entity shall be permitted to alter or construct a comparable residential dwelling unit to comply with 809.2 through 809.4 provided that the minimum...
-
233.3.4 Alterations
accessible route to a residential dwelling unit, the entity shall be permitted to alter or construct a comparable residential dwelling unit to comply with 809.2 through 809.4 provided that the minimum...
-
1002.4.4.2 Side Entry
For example, where a 42 inch (1065 mm) opening is provided, a minimum clear space of 60 inches (1525 mm) in length and 36 inches (915mm) in depth is needed to ensure adequate space for maneuvering...
-
1002.4.4.2 Side Entry
For example, where a 42 inch (1065 mm) opening is provided, a minimum clear space of 60 inches (1525 mm) in length and 36 inches (915mm) in depth is needed to ensure adequate space for maneuvering...
-
1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (840 mm) minimum and 38 inches (965 mm) maximum. EXCEPTIONS: 1....
-
702.1 General
except that the maximum allowable sound level of audible notification appliances complying with section 4-3.2.1 of NFPA 72 (1999 edition) shall have a sound level no more than 110 dB at the minimum...
-
1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (840 mm) minimum and 38 inches (965 mm) maximum. EXCEPTIONS: 1....
-
Entrances
All door openings must provide a minimum width of 32 inches and there must also be enough room for a person using a wheelchair to maneuver to open the door, including 18 inches of clear...