EXCEPTION: Where vandalism is a consideration, a fixed shower head located at 48 in (1220 mm) above the ground shall be permitted in place of a hand-held shower spray unit....
Search Results "Building Permit"
-
1011.7 Outdoor Rinsing Showers
-
§ 35.108(e)(2) Broad construction
Whether an individual has a record of an impairment that substantially limited a major life activity shall be construed broadly to the maximum extent permitted by the ADA and should not...
-
11B-602.2 Clear floor space
Exception: A parallel approach complying with Section 11B-305 shall be permitted at units for children's use where the spout is 30 inches (762 mm) maximum above the finish floor or ground...
-
11B-405.9.2 Curb or barrier
ETA Editor's Note CBC requires either a curb or a barrier for edge protection at ramps, and does not recognize the extended floor or ground surface also permitted by 2010 ADAS....
-
11B-405.7 Landings
A level landing is needed at the accessible door to permit maneuvering and simultaneously door operation....
-
11B-410.6 Doors and gates
Exception: Platform lifts serving two landings maximum and having doors or gates on opposite sides shall be permitted to have self-closing manual doors or gates....
-
11B-902.1 General
Exception: Dining surfaces and work surfaces for children’s use shall be permitted to comply with Section 11B-902.4. [2010 ADAS] Advisory 902.1 General....
-
11B-804.3.1 Clear floor or ground space
Exception: Cabinetry shall be permitted under the kitchen work surface provided that all of the following conditions are met: (a) the cabinetry can be removed without removal or replacement...
-
11B-402.2 Components
Other components of accessible routes, such as ramps (405) and curb ramps (406), are permitted to be more steeply sloped....
-
11B-405.9.2 Curb or barrier
11B-405.9.2] ETA Editor's Note CBC requires either a curb or a barrier for edge protection at ramps, and does not recognize the extended floor or ground surface also permitted...
-
11B-804.3.1 Clear floor or ground space
Exception: Cabinetry shall be permitted under the kitchen work surface provided that all of the following conditions are met: (a) the cabinetry can be removed without removal or...
-
11B-405.7 Landings
A level landing is needed at the accessible door to permit maneuvering and simultaneously door operation. ◼...
-
11B-410.6 Doors and gates
Exception: Platform lifts serving two landings maximum and having doors or gates on opposite sides shall be permitted to have self-closing manual doors or gates....
-
11B-902.1 General
Exception: Dining surfaces and work surfaces for children’s use shall be permitted to comply with Section 11B-902.4. Advisory 11B-902.1 General....
-
502.3 Access Aisle
Two parking spaces shall be permitted to share a common access aisle. Advisory 502.3 Access Aisle. Accessible routes must connect parking spaces to accessible entrances....
-
904.4 Sales and Service Counters
a counter complying with 904.4 would result in a reduction of the number of existing counters at work stations or a reduction of the number of existing mail boxes, the counter shall be permitted...
-
804.3.1 Clear Floor or Ground Space
EXCEPTION: Cabinetry shall be permitted under the kitchen work surface provided that all of the following conditions are met: (a) the cabinetry can be removed without removal or replacement...
-
609.3 Spacing
EXCEPTION: The space between the grab bars and shower controls, shower fittings, and other grab bars above shall be permitted to be 1½ inches (38 mm) minimum....
-
402.2 Components
Other components of accessible routes, such as ramps (405) and curb ramps (406), are permitted to be more steeply sloped....
-
211.3 More Than Minimum Number
EXCEPTION: Where 50 percent of the drinking fountains yields a fraction, 50 percent shall be permitted to be rounded up or down provided that the total number of drinking fountains complying...
-
206.2.15 Golf Facilities
EXCEPTION: Golf car passages complying with 1006.3 shall be permitted to be used for all or part of accessible routes required by 206.2.15....
-
806.2.4 Toilet and Bathing Facilities
Toilet and bathing fixtures required to comply with 603 through 610 shall be permitted to be located in more than one toilet or bathing area, provided that travel between fixtures does not...
-
505.10 Handrail Extensions
In assembly areas, extensions shall not be required for ramp handrails in aisles serving seating where the handrails are discontinuous to provide access to seating and to permit crossovers...
-
NFPA
not be installed in unsprinklered elevator hoistways unless they are installed to activate the elevator hoistway smoke relief equipment or where required by Chapter 30 of the California Building...