Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact....
Search Results "Water Depth"
Commonly Searched Documents
-
606.5 Exposed Pipes and Surfaces
-
11B-606.5 Exposed pipes and surfaces
Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact....
-
604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
- Willoughby Industries ASETW1490FM Ligature-Resistant Floor Mounted Blowout Series Water Closet
-
606.5 Exposed Pipes and Surfaces
Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact....
-
604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and...
-
604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and...
-
604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and...
-
604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
608.6 Shower Spray Unit and Water
Shower spray units shall deliver water that is 120°F (49°C) maximum....
- Figure 904.4 (Exception) Alteration of Sales and Service Counters – Drawing from the U.S. Access Board
-
604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
308.3.2 Obstructed High Reach
floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum and the depth...
-
308.3.2 Obstructed High Reach
floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum and the depth...
-
11B-308.3.2 Obstructed high reach
floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum and the depth...
-
604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
- Willoughby Industries ASETWS-1490-FM-HC Ligature-Resistant Floor Mounted Siphon Jet Water Closet
- American Standard Baby Devoro 1.28 gpf FloWise 10 Inch High Round Front Toilet
- Caroma® USA Caravelle Smart 270 One Piece Toilet
- Zurn Z1209 Vertical Offset Siphon Jet Water Closet Support System
- Kohler Veil™ One-Piece Elongated Dual-Flush Wall-Hung Toilet With Reveal® Quiet-Close™ Seat
- Willoughby Industries ETW-1445-BS-HC Toilet for 45-degree Chase Wall
- Caroma® USA Sydney Low Profile 270 Easy Height Round Front Plus Toilet
-
11B-604.5 Grab bars
Grab bars for water closets shall comply with Section 11B-609. Grab bars shall be provided on the side wall closest to the water closet and on the rear wall....