This section contains technical requirements for obstacles on outdoor recreation access routes, passing spaces, and resting intervals. The vertical alignment of joints in concrete,...
Search Results "Transit Stop"
Commonly Searched Documents
-
1016.5 Obstacles
-
Is there a minimum distance between changes in level?
The standards do not require a minimum horizontal separation between changes in level of a ½” or less. Such level changes may need to be in close proximity, such as at raised...
-
§ 38.173(b)
(b) Where the vehicle covered by paragraph (a) will operate in an accessible station, the design of vehicles shall be coordinated with the boarding platform design such that the...
-
11B-1003.2.1 Boat slips
Where gangways connect to transition plates, landings specified by Section 11B-405.7 shall not be required. 6. ...
-
11B-1003.2.1 Boat slips
Another design solution would be to have two 40 foot (12 m) plus continuous gangways joined together at a float, where the float (as the water level falls) will stop dropping at an elevation...
-
A. Accessible Voting Program
facilities and equipment (including, but not limited to, both permanent equipment such as lifts and elevators and temporary equipment such as portable ramps, traffic cones, wedges, and door stops...
-
M303.3.1 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical.
-
M303.3.1 Vertical (Section-by-Section Analysis)
The MDE NPRM proposed that for equipment with a change in level at the entry to the wheelchair space, level changes of up to ¼ inch high are permitted to be vertical. This provision...
-
§27.19 Compliance with Americans with Disabilities Act requirements and FTA policy.
[55 FR 40763, Oct. 4, 1990, as amended at 56 FR 45621, Sept. 6, 1991; 61 FR 32354, June 24, 1996; 79 FR 21405, Apr. 16, 2014]
-
Changes in Level - Accessible Route Tool
Changes in Level - Accessible Route Tool This handy tool was developed by Evan Terry Associates to assist its surveyors in measuring changes in level along an accessible...
-
Changes in Level - Door Thresholds Tool
Changes in Level - Door Thresholds Tool This handy tool was developed by Evan Terry Associates to assist its surveyors in measuring door thresholds and level changes. It's...
-
6.9 Tread Obstacles
Obstacles on beach access routes and their related resting intervals shall not exceed 1 inch (25 mm) in height measured vertically to the highest point. Where the surface is...
-
M303.3.1 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical.
-
Features of Accessible Parking Spaces for Cars
(plan drawing showing an accessible parking space for cars with a 96 inch wide designated parking space, a 60 inch wide min. marked access aisle and the following...
-
Department of Transportation Disability Law Guidance: Use of "Segways" on Transportation Vehicles
., transit authorities, Amtrak) should permit the “Segway” personal transportation device to be used on transportation vehicles when used as a mobility device by people with disabilities...
-
11B-250.1 General
Exceptions: Curb ramps and blended transitions with detectable warnings complying with Section 11B-247 may be used to connect raised circulation paths and pedestrian crossings within...
- DOT: Pedestrian and Bicycle Funding Opportunities
- Figure 404.2.3 Clear Width of Doorways – Drawing from the U.S. Access Board
- DOT: Accessible Transportation Technologies Research Initiative (ATTRI)
-
§ 35.150 Existing facilities
§ 35.150 Existing facilities. * * * * *
-
8. Amend § 35.150 as follows:
8. Amend § 35.150 as follows: a. Redesignate paragraph (b)(2) as paragraph (b)(3); b. Add the words "or acquisition" after the word "redesign" in the first sentence of...
-
Section 35.150(b)(2) Safe Harbor (Section-by-Section Analysis)
Under the "program accessibility" requirement in title II, each service, program, or activity, when viewed in its entirety, must be readily accessible to and usable by individuals...
-
§35.150 Existing facilities
§35.150 Existing facilities.
-
4) Where the Standard is silent about changes in level
4) Where the Standard is silent about changes in level, such as 604.3 around a water closet or in a toilet compartment: Since there is no mention of the phrase "changes in level...