If a curb ramp is provided, is the running slope of the ramp surface (not counting the side flares) no more than 1:12 or 8.33% [ADA Standards § 4.7.2] Yes No...
Search Results "Slope Meter"
-
A6
-
Wheelchair Spaces
Wheelchair spaces must be level (2% maximum slope in any direction) and adjoining routes and maneuvering spaces must provide flush connections so that maneuvering to and from spaces does...
-
B7-b
Is the slope (up or down the ramp) no more than 1:12? [ADA Standards § 4.7.2] Yes No Note: 1:12 is one inch of vertical height for each 12 inches of length....
-
1016.7.1 Maximum Running Slope and Segment Length
Table 1016.7.1 Maximum Running Slope and Segment Length Running Slope of Outdoor Recreation Access Route Segment Maximum Length of Segment...
-
1016.7.1 Maximum Running Slope and Segment Length
Table 1016.7.1 Maximum Running Slope and Segment Length Running Slope of Outdoor Recreation Access Route Segment Maximum Length of Segment Steeper than But...
-
e-ii
Is the running slope (up or down the ramp) no more than 1:12?...
-
Newly Constructed Tabled Intersections That Contain Pedestrian Street Crossings With Yield or Stop Control (Section-by-Section Analysis)
Newly Constructed Tabled Intersections That Contain Pedestrian Street Crossings With Yield or Stop Control (Section-by-Section Analysis) The 2 percent maximum cross slope requirement...
-
5.1.2 Level or Sloped Entry
Camp shelters providing roll-in access shall have a level or sloped entry that complies with the FSORAG Outdoor Recreation Access Route technical provisions if the camp shelter is in a campground...
-
Surface and Slope [1015.5 and 1015.6]
When the surface of clear ground spaces and turning spaces is constructed of asphalt, concrete, or boards, the slope of the surface must be no steeper than 1:48 (2 percent) in any direction...
-
3 [§ 4.3.7]
3 [§ 4.3.7] The cross slope of the curb ramp is perpendicular to the running slope. Unlike the running slope, which runs along the ramp, the cross slope is measured across the ramp....
-
Ramps M303:3.3, 3.3.1, 3.3.2
Ramp runs would be required to have a running slope not steeper than 1:12 and a cross slope not steeper than 1:48....
-
Submerged Depth
This depth is necessary for individuals using the sloped entry to become buoyant....
-
1009.3.3 Handrails
At least two handrails complying with 505 shall be provided on the sloped entry....
-
11B-1009.3.3 Handrails
At least two handrails complying with Section 11B-505 shall be provided on the sloped entry....
-
Floor or Ground Surface: ADA Standard Section 404.2.4.4
Section 404.2.4.4 covers the current ADA Standards for floor or ground surfaces at door maneuvering clearances.
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12....
-
11B-1009.3.3 Handrails
At least two handrails complying with Section 11B-505 shall be provided on the sloped entry....
-
11B-1009.3.3 Handrails
At least two handrails complying with Section 11B-505 shall be provided on the sloped entry....
-
4 [§ 4.7.2]
To measure the gutter slope, place the level in the same position as the arrow in the illustration, with one end where the gutter meets the ramp and the other end towards the street....
-
1.1.7 Measurement of parking areas
These areas should be considered as a pedestrian walk with a minimum width of 60 in. and a length of approximately 20 ft and with an ADA/ABA - AG maximum slope of 1:48 in both directions...
-
405 Ramps
Technical provisions address running slope, cross slope, handrails, landings, edge protection, and other elements....
-
1009.3.2 Submerged Depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
-
Ramps [4.8]
Where the running slope of an accessible route is more than 5%, it is considered a ramp. Generally, changes in level up to 6 inches can be treated as a curb ramp....
-
11B-1009.3.2 Submerged depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....