If any part of the accessible route - exterior or interior - has a slope greater than 1:20, it is considered a ramp and must meet the requirements for ramps....
Search Results "Ramp Handrail"
-
Ramps
-
SECTION 1012 RAMPS
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for...
-
SECTION 1012 RAMPS
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for...
-
11B-505.5 Clearance
Clearance between handrail gripping surfaces and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
11B-406.5.10 Diagonal curb ramps
Diagonal or corner type curb ramps are perpendicular or parallel curb ramps that are oriented diagonally at an intersection....
-
11B-406.5.10 Diagonal curb ramps
Diagonal or corner type curb ramps are perpendicular or parallel curb ramps that are oriented diagonally at an intersection....
-
11B-505.5 Clearance
Clearance between handrail gripping surfaces and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
11B-505.5 Clearance
Clearance between handrail gripping surfaces and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
Ramps [4.8]
Where the running slope of an accessible route is more than 5%, it is considered a ramp. Generally, changes in level up to 6 inches can be treated as a curb ramp....
-
Accessible Routes: ADA Standard Section 1007.2
Ramp landing slopes specified by 405.7.1 shall be permitted to be 1:20 maximum. 5....
-
11B-1007.2 Accessible routes
Ramp landing slopes specified by Section 11B-405.7.1 shall be permitted to be 1:20 maximum....
-
11B-1007.2 Accessible routes
Ramp landing slopes specified by Section 11B-405.7.1 shall be permitted to be 1:20 maximum....
-
R409.3 Continuity
Handrails shall be continuous within the full length of each ramp run or stair flight....
-
Sections 505.10.2 and 505.10.3
Sections 505.10.2 and 505.10.3 of the 2010 Standards require handrail extensions at both the top and bottom of a flight of stairs....
-
4.9.4(2)
(2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top riser and at least 12 in (305 mm) plus the width of one tread beyond the bottom riser....
-
Stairs
Error/Omission: Handrail extensions are not provided at the top and bottom risers....
-
Doorways: ADA Standard Section 405.7.5
Section 405.7.5 covers the current ADA Standards for doorway maneuvering clearance at ramp landings.
-
R409.10.3 Bottom Extension at Stairways
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
-
R409.10.2 Top Extension at Stairways
At the top of a stair flight, handrails shall extend horizontally above the landing for 305 mm (1.0 ft) minimum beginning directly above the first riser nosing....
-
4.9.4(7)
(7) Handrails shall not rotate within their fittings....
-
R409.4 Height
Top of gripping surfaces of handrails shall be 865 mm (2.8 ft) minimum and 965 mm (3.2 ft) maximum vertically above walking surfaces, ramp surfaces, and stair nosings....
-
Slope: ADA Standard Section 405.7.1
Section 405.7.1 covers the current ADA Standards for the slope in ramp landings.
-
T303.3.2 Handrail and Stanchion Circular Cross Section
Handrails and stanchions with a circular cross section shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (50 mm) maximum....
-
4.9.4(6)
(6) Ends of handrails shall be either rounded or returned smoothly to floor, wall or post....