from side walls. 11B-606.6 Location of bathtub controls and drain. 11B-607.5 Installation height and location of shower...
Search Results "Outdoor Rinsing Shower"
Commonly Searched Documents
-
Verify Rough Plumbing
-
Verify Rough Plumbing
from side walls. 11B-606.6 Location of bathtub controls and drain. 11B-607.5 Installation height and location of shower...
-
4.21.1* General
Accessible shower stalls shall comply with 4.21....
-
610.1 General
Seats in bathtubs and shower compartments shall comply with 610....
-
610.1 General
Seats in bathtubs and shower compartments shall comply with 610....
-
11B-610.1 General
Seats in bathtubs and shower compartments shall comply with Section 11B-610....
-
610.1 General
Seats in bathtubs and shower compartments shall comply with 610....
-
11B-610.1 General
Seats in bathtubs and shower compartments shall comply with Section 11B-610....
-
224.2 Guest Rooms with Mobility Features
Table 224.2 Guest Rooms with Mobility Features Minimum Number of Required Rooms Without Roll-in Showers Minimum Number of Required Rooms...
-
Curbs [4.21.7]
Curbs [4.21.7] Curbs are not permitted at roll-in showers. A slope up to 2% is allowed for drainage....
-
11B-610.1 General
Seats in bathtubs and shower compartments shall comply with Section 11B-610....
-
6.13 Outdoor Constructed Features
Where provided on circulation paths or beach access routes at beaches, outdoor constructed features such as picnic tables, grills or water hydrants, shall comply with technical provisions...
- Amramp Wheelchair Ramps and Mobility Solutions
-
4.4.1 General
Where benches are provided, each shall comply with section 4.4. At least 20 percent of the benches provided at a recreation site shall be connected to an ORAR complying with section...
-
224.2 Guest Rooms with Mobility Features
Table 224.2 Guest Rooms with Mobility Features Total Number of Guest Rooms Provided Minimum Number of Required Rooms Without Roll-In Showers...
-
11B-608.10 Soap dish
Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat....
-
11B-608.10 Soap dish
Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat....
-
11B-608.10 Soap dish
Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat....
-
3.4.8 Viewing Areas Accessed by Vehicular Ways
a viewing area is accessed by a vehicular way and parking spaces are provided adjacent to the viewing area, the accessible parking spaces shall be connected to the viewing areas by an outdoor...
-
F244.3 Outdoor Constructed Features in Common Use and Public Use Areas
This section contains the scoping requirements for outdoor constructed features provided in common use and public use areas that serve camping units with mobility features....
-
F245.3 Outdoor Constructed Features in Common Use and Public Use Areas
This section contains the scoping requirements for outdoor constructed features provided in common use and public use areas that serve picnic units with mobility features....
-
TRANSFER STALLS
[See subsections ...]
-
4.21.5 Controls
4.21.5 Controls. None of the respondents indicated that there were any variations from ADAAG regarding the controls.
- Collapsible Water Retainer Shower Dam for Shower Threshold